Visual Quality and Symptomatology Following Implantation of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens

Background/Objectives: This study aimed to evaluate the visual quality and symptomatol ogy of a non-diffractive extended depth-of-focus (EDoF) intraocular lens (IOL), the Elon 877PEY (Medicontur, Zsámbék, Hungary), three months after implantation. Methods: A cross-sectional case series study was con...

Descripción completa

Detalles Bibliográficos
Autores: Cano Ortiz, Antonio, Sánchez Ventosa, Álvaro, González Cruces, Timoteo, Villalba González, Marta, Aguilar Salazar, Francisco Javier, Prados Carmona, Juan J., Carpena-Torres, Carlos, Carracedo, Gonzalo, Villarrubia, Alberto
Tipo de recurso: artículo
Fecha de publicación:2025
País:España
Institución:Universidad Loyola Andalucía
Repositorio:Brújula
OAI Identifier:oai:repositorio.uloyola.es:20.500.12412/6893
Acceso en línea:https://hdl.handle.net/20.500.12412/6893
Access Level:acceso abierto
Palabra clave:Extended range
EDOF
Defocus curve
Visual acuity
Contrast sensitivity
Rango extendido
Profundidad de campo extendida
Curva de desenfoque
Agudeza visual
Sensibilidad al contraste
Descripción
Sumario:Background/Objectives: This study aimed to evaluate the visual quality and symptomatol ogy of a non-diffractive extended depth-of-focus (EDoF) intraocular lens (IOL), the Elon 877PEY (Medicontur, Zsámbék, Hungary), three months after implantation. Methods: A cross-sectional case series study was conducted, with measurements taken three months post-implantation of the Elon IOL. A total of 56 implanted eyes from 28 patients (mean age: 64.5 ± 9.5 years) were included in the statistical analysis. The variables analyzed to assess the effectiveness of the Elon IOL included high-contrast visual acuity, contrast sensitivity, the defocus curve, and visual symptoms. Results: Three months after implanta tion, the mean residual sphere was 0.00 ± 0.33 D, while the mean residual cylinder was −0.25 ± 0.41 D. Without correction, patients achieved monocular decimal visual acuity values of 0.94 ± 0.26 for distance, 0.79 ± 0.17 for intermediate, and 0.58 ± 0.15 for near vision. The mean uncorrected contrast sensitivity was 1.61 ± 0.15 log. The defocus curve showed visual acuity exceeding 0.80 decimal (0.10 logMAR) over a 2.00 D range and above 0.63 decimal (0.20 logMAR) over a 2.50 D range. The most frequently reported symp toms, with mild severity and bothersomeness, were glare, starbursts, halos, and focusing difficulties. Conclusions: Patients implanted with the Elon IOL achieved satisfactory visual quality at all distances, comparable to outcomes reported for other EDoF IOLs in the scientific literature.