Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial
Objective To assess the effect of continuous positive airway pressure (CPAP) on 24 hour ambulatory blood pressure monitoring values in a large number of patients with untreated systemic hypertension of new onset and obstructive sleep apnoea. Design Multicentre, double blind, randomised, placebo cont...
| Authors: | , , , , , , , , , , , , |
|---|---|
| Format: | article |
| Publication Date: | 2010 |
| Country: | España |
| Institution: | Universidad de Cantabria (UC) |
| Repository: | UCrea Repositorio Abierto de la Universidad de Cantabria |
| Language: | English |
| OAI Identifier: | oai:repositorio.unican.es:10902/33000 |
| Online Access: | https://hdl.handle.net/10902/33000 |
| Access Level: | Open access |
| id |
ES_127c2c814ecd7210f51691c2e17886e5 |
|---|---|
| oai_identifier_str |
oai:repositorio.unican.es:10902/33000 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trialDurán-Cantolla, JoaquínAizpuru, FelipeMontserrat, José MaríaBallester, EugeniTerán-Santos, JoaquinAguirregomoscorta, Jose IgnacioGonzález Martínez, Mónica|||0000-0003-1516-0181Lloberes, PatriciaMasa, Juan FernandoPeña, Mónica de laCarrizo, SantiagoMayos, MercedesBarbé, FerránObjective To assess the effect of continuous positive airway pressure (CPAP) on 24 hour ambulatory blood pressure monitoring values in a large number of patients with untreated systemic hypertension of new onset and obstructive sleep apnoea. Design Multicentre, double blind, randomised, placebo controlled trial. Setting Eleven general hospitals in Spain between 2004 and 2007. Participants 340 patients recently diagnosed as having systemic hypertension by a general practitioner (systolic blood pressure ≥140 mm Hg, diastolic blood pressure ≥90 mm Hg, or both) and an apnoea-hypopnoea index per hour of sleep of >15 events/hour. Intervention Patients were assigned to CPAP (n=169) or sham CPAP (n=171) for three months. Main outcome measurements Net changes in the different 24 hour ambulatory blood pressure monitoring values from baseline to three months of optimal or sham CPAP. Results 277 (81%) of the 340 patients randomised were men; the patients had a mean age of 52.4 (SD 10.5) years, a body mass index of 31.9 (5.7), an Epworth sleepiness scale score of 10.1 (4.3), an apnoea-hypopnoea index of 43.5 (24.5). No differences between groups were seen at baseline. Compared with placebo and analysed by intention to treat, the mean 24 hour ambulatory blood pressure of the CPAP group decreased by 1.5 (95% confidence interval: 0.4 to 2.7) mm Hg (P=0.01). The mean 24 hour ambulatory blood pressure monitoring measures decreased by 2.1 mm Hg (0.4 to 3.7) mm Hg (P=0.01) for systolic pressure and 1.3 (0.2 to 2.3) mm Hg (P=0.02) for diastolic blood pressure. Mean nocturnal blood pressure decreased by 2.1 (0.5 to 3.6) mm Hg (P=0.01). Conclusions CPAP produced a statistically significant reduction in blood pressure in patients with systemic hypertension and obstructive sleep apnoea. This reduction is small and did not achieve the 3 mm Hg drop in mean 24 hour ambulatory blood pressure that the trial was powered to detect. Consequently, these results may have uncertain clinical relevance. However, taking into account the prevalence of hypertension and the likelihood of comorbidities, the decrease in blood pressure, although minimal, may be beneficial.Funding: The study was sponsored by the Spanish Ministry of Health (PI041110), the Basque Government’s Department of Health (20031103), and the Spanish Respiratory Society (SEPAR 2005). The sponsors had no role in the design and conduct of the study; in the collection, analysis, and interpretation of the data; or in the preparation, review, and approval of the manuscript. The opinions, results, and conclusions are those of the authors.BMJ Publishing Group LtdUniversidad de Cantabria20102010-01-01journal articlehttp://purl.org/coar/resource_type/c_6501NAhttp://purl.org/coar/version/c_be7fb7dd8ff6fe43info:eu-repo/semantics/articlehttps://hdl.handle.net/10902/33000BMJ, 2010, 341, c5991reponame:UCrea Repositorio Abierto de la Universidad de Cantabriainstname:Universidad de Cantabria (UC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial 4.0 Internationalhttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessoai:repositorio.unican.es:10902/330002026-06-02T12:39:31Z |
| dc.title.none.fl_str_mv |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| title |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| spellingShingle |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial Durán-Cantolla, Joaquín |
| title_short |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| title_full |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| title_fullStr |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| title_full_unstemmed |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| title_sort |
Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial |
| dc.creator.none.fl_str_mv |
Durán-Cantolla, Joaquín Aizpuru, Felipe Montserrat, José María Ballester, Eugeni Terán-Santos, Joaquin Aguirregomoscorta, Jose Ignacio González Martínez, Mónica|||0000-0003-1516-0181 Lloberes, Patricia Masa, Juan Fernando Peña, Mónica de la Carrizo, Santiago Mayos, Mercedes Barbé, Ferrán |
| author |
Durán-Cantolla, Joaquín |
| author_facet |
Durán-Cantolla, Joaquín Aizpuru, Felipe Montserrat, José María Ballester, Eugeni Terán-Santos, Joaquin Aguirregomoscorta, Jose Ignacio González Martínez, Mónica|||0000-0003-1516-0181 Lloberes, Patricia Masa, Juan Fernando Peña, Mónica de la Carrizo, Santiago Mayos, Mercedes Barbé, Ferrán |
| author_role |
author |
| author2 |
Aizpuru, Felipe Montserrat, José María Ballester, Eugeni Terán-Santos, Joaquin Aguirregomoscorta, Jose Ignacio González Martínez, Mónica|||0000-0003-1516-0181 Lloberes, Patricia Masa, Juan Fernando Peña, Mónica de la Carrizo, Santiago Mayos, Mercedes Barbé, Ferrán |
| author2_role |
author author author author author author author author author author author author |
| dc.contributor.none.fl_str_mv |
Universidad de Cantabria |
| description |
Objective To assess the effect of continuous positive airway pressure (CPAP) on 24 hour ambulatory blood pressure monitoring values in a large number of patients with untreated systemic hypertension of new onset and obstructive sleep apnoea. Design Multicentre, double blind, randomised, placebo controlled trial. Setting Eleven general hospitals in Spain between 2004 and 2007. Participants 340 patients recently diagnosed as having systemic hypertension by a general practitioner (systolic blood pressure ≥140 mm Hg, diastolic blood pressure ≥90 mm Hg, or both) and an apnoea-hypopnoea index per hour of sleep of >15 events/hour. Intervention Patients were assigned to CPAP (n=169) or sham CPAP (n=171) for three months. Main outcome measurements Net changes in the different 24 hour ambulatory blood pressure monitoring values from baseline to three months of optimal or sham CPAP. Results 277 (81%) of the 340 patients randomised were men; the patients had a mean age of 52.4 (SD 10.5) years, a body mass index of 31.9 (5.7), an Epworth sleepiness scale score of 10.1 (4.3), an apnoea-hypopnoea index of 43.5 (24.5). No differences between groups were seen at baseline. Compared with placebo and analysed by intention to treat, the mean 24 hour ambulatory blood pressure of the CPAP group decreased by 1.5 (95% confidence interval: 0.4 to 2.7) mm Hg (P=0.01). The mean 24 hour ambulatory blood pressure monitoring measures decreased by 2.1 mm Hg (0.4 to 3.7) mm Hg (P=0.01) for systolic pressure and 1.3 (0.2 to 2.3) mm Hg (P=0.02) for diastolic blood pressure. Mean nocturnal blood pressure decreased by 2.1 (0.5 to 3.6) mm Hg (P=0.01). Conclusions CPAP produced a statistically significant reduction in blood pressure in patients with systemic hypertension and obstructive sleep apnoea. This reduction is small and did not achieve the 3 mm Hg drop in mean 24 hour ambulatory blood pressure that the trial was powered to detect. Consequently, these results may have uncertain clinical relevance. However, taking into account the prevalence of hypertension and the likelihood of comorbidities, the decrease in blood pressure, although minimal, may be beneficial. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010 2010-01-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 NA http://purl.org/coar/version/c_be7fb7dd8ff6fe43 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/10902/33000 |
| url |
https://hdl.handle.net/10902/33000 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial 4.0 International http://creativecommons.org/licenses/by-nc/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial 4.0 International http://creativecommons.org/licenses/by-nc/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
BMJ Publishing Group Ltd |
| publisher.none.fl_str_mv |
BMJ Publishing Group Ltd |
| dc.source.none.fl_str_mv |
BMJ, 2010, 341, c5991 reponame:UCrea Repositorio Abierto de la Universidad de Cantabria instname:Universidad de Cantabria (UC) |
| instname_str |
Universidad de Cantabria (UC) |
| reponame_str |
UCrea Repositorio Abierto de la Universidad de Cantabria |
| collection |
UCrea Repositorio Abierto de la Universidad de Cantabria |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869403621395791872 |
| score |
15.812455 |