Determination of the maximum steady state of lactate (MLSS) in saliva: An alternative to blood lactate determination

Based on previous research which shows parallelism between the saliva and blood lactate response during incremental exercise, we hypothesized that a "maximum salivary lactate steady state" (saliva-MLSS) might exist. Thus, the aim of the present investigation was to establish 1) which lower...

Descripción completa

Detalles Bibliográficos
Autores: Pérez Ruiz, Margarita, Lucía Mulas, Alejandro, Carvajal, Alfredo, Pardo Gil, Francisco Javier, Chicharro, José L.
Tipo de recurso: artículo
Fecha de publicación:1999
País:España
Institución:Universidad Europea (UEM)
Repositorio:ABACUS. Repositorio de Producción Científica
Idioma:inglés
OAI Identifier:oai:abacus.universidadeuropea.com:11268/6008
Acceso en línea:http://hdl.handle.net/11268/6008
Access Level:acceso abierto
Palabra clave:Saliva
Fisiología humana
Medicina deportiva
Descripción
Sumario:Based on previous research which shows parallelism between the saliva and blood lactate response during incremental exercise, we hypothesized that a "maximum salivary lactate steady state" (saliva-MLSS) might exist. Thus, the aim of the present investigation was to establish 1) which lower limit for the increase in salivary lactate concentration during a constant workload (i.e., from the 10th to the 20th min) test could be used to determine the saliva-MLSS and 2) if the exercise intensity corresponding to the saliva-MLSS is identical to that evoking the (blood) MLSS. Twelve male amateur athletes of mean (+/-SD) age 24+/-5 year were selected for the study. Based on the results of a previous maximal cycle ergometer test for lactate threshold (LT) determination, each subject performed consecutive constant workload tests of 20-min duration on separate days for MLSS determination, Blood and saliva (25 mu l) samples were collected at 0, 10, and 20 min during the tests for lactate determination. A Student's t-test for paired data demonstrated that a salivary lactate increase of 0.8 mM corresponded to the saliva-MLSS. At this value, indeed, no significant differences were observed between the mean (V) over dot O-2, and W values corresponding to the MLSS and the saliva-MLSS. In conclusion, the present findings indicate that 0.8 mM is the lower limit for the increase in saliva lactate concentration during a constant load test and thus is that which might be used as a reference to determine saliva-MLSS. Furthermore, saliva-MLSS might be used as an alternative to MLSS determination in blood samples.