Optimal energy efficiency of isolated PAT systems by SEIG excitation tuning

[EN] The use of pump working as turbine (PAT) was identified by many researchers as a way to improve the energy efficiency in the water systems. However, the majority of the researches consider the hydraulic machine connected to the electrical grid, which may not fit best when these recovery systems...

Descripción completa

Detalles Bibliográficos
Autores: Fernandes, João F.P., Ferreira, F., Ramos, Helena M., Costa Branco, P.J., Pérez-Sánchez, Modesto|||0000-0001-8316-7778, López Jiménez, Petra Amparo|||0000-0002-7043-3683
Tipo de recurso: artículo
Fecha de publicación:2019
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/141515
Acceso en línea:https://riunet.upv.es/handle/10251/141515
Access Level:acceso abierto
Palabra clave:Energy efficiency
Off-grid PAT
Self-excited induction generator (SEIG)
Water-energy nexus
INGENIERIA HIDRAULICA
Descripción
Sumario:[EN] The use of pump working as turbine (PAT) was identified by many researchers as a way to improve the energy efficiency in the water systems. However, the majority of the researches consider the hydraulic machine connected to the electrical grid, which may not fit best when these recovery systems are located in rural or remote areas. To improve the efficiency in these recovery systems for rural areas, this research contributes for a further study and optimization of the off-grid PAT systems with induction generators. The current manuscript proposes a methodology to obtain the best efficiency of the PAT-SEIG (Self-Excited Induction Generator) system when operating under different speeds and loads. For these systems, the selection of capacitors for the SEIG is critical to maximizing the energy efficiency. A methodology is proposed to estimate and select the correct SEIG model parameters and, thus, compute the best capacitor values to improve the PAT-SEIG energy efficiency. Special attention is given to the impact the SEIG parameters have in the efficiency of the recovery system. The accuracy of the analytical model improved, reducing the error between analytical and experimental results from 50.8% (for a model with constant parameters) to 13.2% (with parameters changing according to the operating point of the system). These results showed an increase of the overall PAT system efficiency from 26% to 40% for the analyzed case study.