Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)

Study of the macular retinal thickness measured by Optical Coherence Tomography after refractive surgery with ICL phakic lens INTRODUCTION Phakic intraocular lenses (PIOLs) have been shown to be an effective surgical option for the treatment of ametropia of various refractive ranges. Several publish...

ver descrição completa

Detalhes bibliográficos
Autor: Maseras Bruguera, Xavier
Tipo de documento: tese
Data de publicação:2016
País:España
Recursos:Universitat Autònoma de Barcelona
Repositório:Dipòsit Digital de Documents de la UAB
Idioma:espanhol
OAI Identifier:oai:ddd.uab.cat:165279
Acesso em linha:https://ddd.uab.cat/record/165279
Access Level:Acceso aberto
Palavra-chave:Edema macular
Miopia
Oftalmologia
id ES_0dc42e56386a5a8fce004dac0ab3a2f7
oai_identifier_str oai:ddd.uab.cat:165279
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
title Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
spellingShingle Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
Maseras Bruguera, Xavier
Edema macular
Miopia
Oftalmologia
title_short Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
title_full Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
title_fullStr Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
title_full_unstemmed Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
title_sort Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)
dc.creator.none.fl_str_mv Maseras Bruguera, Xavier
author Maseras Bruguera, Xavier
author_facet Maseras Bruguera, Xavier
author_role author
dc.contributor.none.fl_str_mv Universitat Autònoma de Barcelona. Departament de Cirurgia
Cámara Hermoso, Julio de la
Jürgens Mestre, Ignasi
dc.subject.none.fl_str_mv Edema macular
Miopia
Oftalmologia
topic Edema macular
Miopia
Oftalmologia
description Study of the macular retinal thickness measured by Optical Coherence Tomography after refractive surgery with ICL phakic lens INTRODUCTION Phakic intraocular lenses (PIOLs) have been shown to be an effective surgical option for the treatment of ametropia of various refractive ranges. Several published studies have confirmed the Visian Implantable Collamer Lens (ICL; ST16R Surgical AG, Nidau, Switzerland) ICL implantation as an effective treatment to correct myopia, hyperopia or astigmatism. PURPOSE: To determine macular thickness changes after posterior chamber phakic intraocular lens implantation for the correction of ametropia using spectral domain optical coherence tomography (OCT). MATERIAL AND METHODS: Prospective study was conducted in 111 eyes of 58 patients underwent implantation of the implantable Collamer lens (ICL). Patients were evaluated before surgery and after surgery at week 4 and week 12. Visual acuity (VA), intraocular pressure, anterior chamber depth, pupil diameter and macular thickness with Spectralis coherence tomography were measured. RESULTS: 111 eyes from 58 patients have been studied. The mean age is 33,8 ± 6.3 years (26-50) . Mean preoperative spherical equivalent refraction was -7,793 ± 5,268. Mean postoperative spherical equivalent refraction 3 months after the surgery was -0.094 ± 0,788 D. The foveal macular thickness was de 287± 24 µm before de surgery and 290 y 293 µm at 1 and 3 months after the surgery without any significant difference in any of the areas. Uncorrected visual acuity improved in all cases and no changes in macular thickness and macular volume were found after the surgery. There were no cases of cystoid macular edema. CONCLUSIONS: The implantation of ICL has been shown to be an effective surgical option for the treatment of refractive errors. No cases of macular edema develops after surgery in our patients. The spectral domain optical coherence tomography was notable to detect any increase in macular thickness in this study period.
publishDate 2016
dc.date.none.fl_str_mv 2
2016-01-01
2016
2016-01-01
dc.type.none.fl_str_mv Tesi doctoral
http://purl.org/coar/resource_type/c_db06
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
dc.identifier.none.fl_str_mv https://ddd.uab.cat/record/165279
url https://ddd.uab.cat/record/165279
dc.language.none.fl_str_mv Español
spa
language_invalid_str_mv Español
language spa
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
https://creativecommons.org/licenses/by-nc-nd/3.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
https://creativecommons.org/licenses/by-nc-nd/3.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universitat Autònoma de Barcelona
publisher.none.fl_str_mv Universitat Autònoma de Barcelona
dc.source.none.fl_str_mv reponame:Dipòsit Digital de Documents de la UAB
instname:Universitat Autònoma de Barcelona
instname_str Universitat Autònoma de Barcelona
reponame_str Dipòsit Digital de Documents de la UAB
collection Dipòsit Digital de Documents de la UAB
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869403358134009856
spelling Estudio de los grosores retinianos maculares con OCT tras cirugía referactiva con lente fáquica tipo ICL (TM)Maseras Bruguera, XavierEdema macularMiopiaOftalmologiaStudy of the macular retinal thickness measured by Optical Coherence Tomography after refractive surgery with ICL phakic lens INTRODUCTION Phakic intraocular lenses (PIOLs) have been shown to be an effective surgical option for the treatment of ametropia of various refractive ranges. Several published studies have confirmed the Visian Implantable Collamer Lens (ICL; ST16R Surgical AG, Nidau, Switzerland) ICL implantation as an effective treatment to correct myopia, hyperopia or astigmatism. PURPOSE: To determine macular thickness changes after posterior chamber phakic intraocular lens implantation for the correction of ametropia using spectral domain optical coherence tomography (OCT). MATERIAL AND METHODS: Prospective study was conducted in 111 eyes of 58 patients underwent implantation of the implantable Collamer lens (ICL). Patients were evaluated before surgery and after surgery at week 4 and week 12. Visual acuity (VA), intraocular pressure, anterior chamber depth, pupil diameter and macular thickness with Spectralis coherence tomography were measured. RESULTS: 111 eyes from 58 patients have been studied. The mean age is 33,8 ± 6.3 years (26-50) . Mean preoperative spherical equivalent refraction was -7,793 ± 5,268. Mean postoperative spherical equivalent refraction 3 months after the surgery was -0.094 ± 0,788 D. The foveal macular thickness was de 287± 24 µm before de surgery and 290 y 293 µm at 1 and 3 months after the surgery without any significant difference in any of the areas. Uncorrected visual acuity improved in all cases and no changes in macular thickness and macular volume were found after the surgery. There were no cases of cystoid macular edema. CONCLUSIONS: The implantation of ICL has been shown to be an effective surgical option for the treatment of refractive errors. No cases of macular edema develops after surgery in our patients. The spectral domain optical coherence tomography was notable to detect any increase in macular thickness in this study period.Estudio de los grosores retinianos maculares con tomografía de coherencia óptica tras cirugía refractiva con lente fáquica tipo ICL™ INTRODUCCIÓN Las lentes intraoculares fáquicas (PIOL's) han mostrado ser una efectiva opción quirúrgica para el tratamiento de la ametropía de distintos rangos refractivos. Algunos estudios publicados han confirmado la implantación de la Visian® Implantable Collamer Lens (ICL™; STAAR Surgical AG, Nidau, Suiza) como un tratamiento eficaz para la corrección de la miopía, la hipermetropía o el astigmatismo OBJETIVO Determinar los cambios de grosor macular después del implante de la lente intraocular fáquica de cámara posterior para la corrección de la ametropía utilizando la tomografía de coherencia óptica (OCT) MATERIAL Y MÉTODOS Estudio prospectivo realizado en 111 ojos de 58 pacientes que se sometieron a cirugía con implante de ICL. Los pacientes eran evaluados antes de la cirugía y después de la cirugía a la semana 4 y a la semana 12. La agudeza visual, la presión intraocular, la profundidad de la cámara anterior, el diámetro pupilar y el grosor macular evaluado con tomografía de coherencia óptica eran evaluados RESULTADOS Se han estudiado 111 ojos de 58 pacientes. La edad media era de 33,8 ± 6.3 years (26-50). El equivalente esférico medio preoperatorio era -7,793 ± 5,268. El equivalente medio postoperatorio a los 3 meses de la cirugía era -0.094 ± 0,788 D. El grosor foveal antes de la ciugía era de 287± 24 µm y de 290 y 293 µm respectivamente al mes y a los 3 meses de la cirugía sin encontrarse diferencias significativas en ninguno de los sectores. La agudeza visual no corregida mejoró en todos los casos y no se detectaron cambios ni en el grosor macular ni en el volumen macular tras la cirugía. No se han encontrado casos de edema macular. CONCLUSIONES El implante de la lente tipo ICL se ha mostrado como una opción quirúrgica efectiva para el tratamiento de los errores refractivos. No se han desarrollado casos de edema macular tras la cirugía en nuestros pacientes. La tomografía de coherencia óptica de dominio espectral nos ha permitido detectar cualquier incremento significativo de grosor en este periodo de estudioUniversitat Autònoma de BarcelonaUniversitat Autònoma de Barcelona. Departament de CirurgiaCámara Hermoso, Julio de laJürgens Mestre, Ignasi 22016-01-0120162016-01-01Tesi doctoralhttp://purl.org/coar/resource_type/c_db06VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/doctoralThesisapplication/pdfhttps://ddd.uab.cat/record/165279reponame:Dipòsit Digital de Documents de la UABinstname:Universitat Autònoma de BarcelonaEspañolspaopen accesshttp://purl.org/coar/access_right/c_abf2Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, i la comunicació pública de l'obra, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. No es permet la creació d'obres derivades.https://creativecommons.org/licenses/by-nc-nd/3.0/info:eu-repo/semantics/openAccessoai:ddd.uab.cat:1652792026-06-06T12:50:31Z
score 15.300719