A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.

The objective of this study was to evaluate the effects on the posterior tibial slope of different distances from the joint line to start the osteotomy and of varying the placement of the opening wedge in high tibial osteotomy. Starting the osteotomy more distally and an incorrect location for the t...

Descripción completa

Detalles Bibliográficos
Autores: Erquicia JI, Gil-Gonzalez S, Ibañez M, Leal-Blanquet J, Combalia A, Monllau JC, Pelfort X
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2022
País:España
Institución:Institut d'Investigació i Innovació Parc Taulí (I3PT)
Repositorio:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí
OAI Identifier:oai:i3pt.fundanetsuite.com:p1624
Acceso en línea:https://i3pt.portalinvestigacion.com/publicaciones/1624
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145351159&doi=10.1186%2fs40634-022-00562-z&partnerID=40&md5=469b745ebcc0d0c74b5ce50958734708
Access Level:acceso abierto
Palabra clave:Anterior cruciate ligament, Cadaveric study, Lateral knee X-ray, Medial starting point, Opening-wedge high tibial osteotomy, Osteotomy, Posterior tibial slope, Proximal anatomical axis
id ES_0d257db8d3376661c7c87eed3ac689ff
oai_identifier_str oai:i3pt.fundanetsuite.com:p1624
network_acronym_str ES
network_name_str España
repository_id_str
spelling A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.Erquicia JIGil-Gonzalez SIbañez MLeal-Blanquet JCombalia AMonllau JCPelfort XAnterior cruciate ligament, Cadaveric study, Lateral knee X-ray, Medial starting point, Opening-wedge high tibial osteotomy, Osteotomy, Posterior tibial slope, Proximal anatomical axisThe objective of this study was to evaluate the effects on the posterior tibial slope of different distances from the joint line to start the osteotomy and of varying the placement of the opening wedge in high tibial osteotomy. Starting the osteotomy more distally and an incorrect location for the tibial opening wedge were hypothesized to increase the posterior tibial slope.WILEY2022info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://i3pt.portalinvestigacion.com/publicaciones/1624https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145351159&doi=10.1186%2fs40634-022-00562-z&partnerID=40&md5=469b745ebcc0d0c74b5ce50958734708Journal of Experimental OrthopaedicsISSN: 21971153reponame:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulíinstname:Institut d'Investigació i Innovació Parc Taulí (I3PT)Inglésinfo:eu-repo/semantics/openAccessoai:i3pt.fundanetsuite.com:p16242026-06-21T15:30:37Z
dc.title.none.fl_str_mv A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
title A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
spellingShingle A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
Erquicia JI
Anterior cruciate ligament, Cadaveric study, Lateral knee X-ray, Medial starting point, Opening-wedge high tibial osteotomy, Osteotomy, Posterior tibial slope, Proximal anatomical axis
title_short A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
title_full A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
title_fullStr A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
title_full_unstemmed A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
title_sort A lower starting point for the medial cut increases the posterior slope in opening-wedge high tibial osteotomy: a cadaveric study.
dc.creator.none.fl_str_mv Erquicia JI
Gil-Gonzalez S
Ibañez M
Leal-Blanquet J
Combalia A
Monllau JC
Pelfort X
author Erquicia JI
author_facet Erquicia JI
Gil-Gonzalez S
Ibañez M
Leal-Blanquet J
Combalia A
Monllau JC
Pelfort X
author_role author
author2 Gil-Gonzalez S
Ibañez M
Leal-Blanquet J
Combalia A
Monllau JC
Pelfort X
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv Anterior cruciate ligament, Cadaveric study, Lateral knee X-ray, Medial starting point, Opening-wedge high tibial osteotomy, Osteotomy, Posterior tibial slope, Proximal anatomical axis
topic Anterior cruciate ligament, Cadaveric study, Lateral knee X-ray, Medial starting point, Opening-wedge high tibial osteotomy, Osteotomy, Posterior tibial slope, Proximal anatomical axis
description The objective of this study was to evaluate the effects on the posterior tibial slope of different distances from the joint line to start the osteotomy and of varying the placement of the opening wedge in high tibial osteotomy. Starting the osteotomy more distally and an incorrect location for the tibial opening wedge were hypothesized to increase the posterior tibial slope.
publishDate 2022
dc.date.none.fl_str_mv 2022
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://i3pt.portalinvestigacion.com/publicaciones/1624
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145351159&doi=10.1186%2fs40634-022-00562-z&partnerID=40&md5=469b745ebcc0d0c74b5ce50958734708
url https://i3pt.portalinvestigacion.com/publicaciones/1624
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145351159&doi=10.1186%2fs40634-022-00562-z&partnerID=40&md5=469b745ebcc0d0c74b5ce50958734708
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv WILEY
publisher.none.fl_str_mv WILEY
dc.source.none.fl_str_mv Journal of Experimental Orthopaedics
ISSN: 21971153
reponame:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí
instname:Institut d'Investigació i Innovació Parc Taulí (I3PT)
instname_str Institut d'Investigació i Innovació Parc Taulí (I3PT)
reponame_str r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí
collection r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869403323559313408
score 15.812429