A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking
[EN] Purpose: This study investigated the feasibility of feature tracking cardiac computed tomography (CCT)-derived LV global and regional strain and its agreement with feature tracking cardiac magnetic resonance (CMR)-derived measurements. Methods: CMR images and CCT images were acquired from 15 ad...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/227548 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/227548 |
| Access Level: | acceso abierto |
| Palabra clave: | Cardiac magnetic resonance Cardiac computed tomography Feature tracking Left ventricular function Myocardial strain Reproducibility |
| id |
ES_0cbcad794f85b3d2a5fd9bf3e7d58b81 |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/227548 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature trackingDel-Canto, IreneLópez-Lereu, María P.Monmeneu, José V.Maceira, AliciaMoratal, David|||0000-0002-2825-3646Cardiac magnetic resonanceCardiac computed tomographyFeature trackingLeft ventricular functionMyocardial strainReproducibility[EN] Purpose: This study investigated the feasibility of feature tracking cardiac computed tomography (CCT)-derived LV global and regional strain and its agreement with feature tracking cardiac magnetic resonance (CMR)-derived measurements. Methods: CMR images and CCT images were acquired from 15 adult patients (50% women, mean age: 65 +/- 9 years). Cardiac LV global and segmental circumferential and longitudinal strain and strain rate were assessed on CCT and CMR using feature tracking (FT) technology. Agreement between the measurements from two different modalities was evaluated using Bland-Altman analysis and intraclass correlation coefficient (ICC). Results: Strain/strain rate analysis could be accomplished in every subject with both techniques. Agreement between CMR-FT and CCT-FT was strong for global circumferential strain (ICC > 0.75), while other global strain features displayed moderate inter-technique correlation (ICC > 0.50). On Bland-Altman analysis, strain analysis derived from CCT-FT showed a lower measurement of LV global longitudinal strain and strain rate in comparison with CMR-FT (mean difference: 5.32% and 0.71 s(-1), respectively). Additionally, reproducibility of segmental strain was better for myocardial and endocardial than epicardial walls. Conclusions: CCT-FT is a feasible technique, with good agreement with analogous CMR-FT-derived parameters, especially for global measurements, and could be an acceptable alternative for strain assessment.Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. The authors declare that no funds, grants, or other support was received during the preparation of this manuscript.Springer-VerlagDepartamento de Ingeniería ElectrónicaCentro de Biomateriales e Ingeniería TisularEscuela Técnica Superior de Ingeniería IndustrialUniversitat Politècnica de ValènciaRepositorio Institucional de la Universitat Politècnica de València Riunet20252025-08-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/227548reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento (by)http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/2275482026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| title |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| spellingShingle |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking Del-Canto, Irene Cardiac magnetic resonance Cardiac computed tomography Feature tracking Left ventricular function Myocardial strain Reproducibility |
| title_short |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| title_full |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| title_fullStr |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| title_full_unstemmed |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| title_sort |
A comparative analysis of myocardial strain and strain rate in cardiac computed tomography and magnetic resonance feature tracking |
| dc.creator.none.fl_str_mv |
Del-Canto, Irene López-Lereu, María P. Monmeneu, José V. Maceira, Alicia Moratal, David|||0000-0002-2825-3646 |
| author |
Del-Canto, Irene |
| author_facet |
Del-Canto, Irene López-Lereu, María P. Monmeneu, José V. Maceira, Alicia Moratal, David|||0000-0002-2825-3646 |
| author_role |
author |
| author2 |
López-Lereu, María P. Monmeneu, José V. Maceira, Alicia Moratal, David|||0000-0002-2825-3646 |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Ingeniería Electrónica Centro de Biomateriales e Ingeniería Tisular Escuela Técnica Superior de Ingeniería Industrial Universitat Politècnica de València Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Cardiac magnetic resonance Cardiac computed tomography Feature tracking Left ventricular function Myocardial strain Reproducibility |
| topic |
Cardiac magnetic resonance Cardiac computed tomography Feature tracking Left ventricular function Myocardial strain Reproducibility |
| description |
[EN] Purpose: This study investigated the feasibility of feature tracking cardiac computed tomography (CCT)-derived LV global and regional strain and its agreement with feature tracking cardiac magnetic resonance (CMR)-derived measurements. Methods: CMR images and CCT images were acquired from 15 adult patients (50% women, mean age: 65 +/- 9 years). Cardiac LV global and segmental circumferential and longitudinal strain and strain rate were assessed on CCT and CMR using feature tracking (FT) technology. Agreement between the measurements from two different modalities was evaluated using Bland-Altman analysis and intraclass correlation coefficient (ICC). Results: Strain/strain rate analysis could be accomplished in every subject with both techniques. Agreement between CMR-FT and CCT-FT was strong for global circumferential strain (ICC > 0.75), while other global strain features displayed moderate inter-technique correlation (ICC > 0.50). On Bland-Altman analysis, strain analysis derived from CCT-FT showed a lower measurement of LV global longitudinal strain and strain rate in comparison with CMR-FT (mean difference: 5.32% and 0.71 s(-1), respectively). Additionally, reproducibility of segmental strain was better for myocardial and endocardial than epicardial walls. Conclusions: CCT-FT is a feasible technique, with good agreement with analogous CMR-FT-derived parameters, especially for global measurements, and could be an acceptable alternative for strain assessment. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025 2025-08-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/227548 |
| url |
https://riunet.upv.es/handle/10251/227548 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Springer-Verlag |
| publisher.none.fl_str_mv |
Springer-Verlag |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869403301062115328 |
| score |
15,812455 |