Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus

Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients.; Methods. Fifty-two right eyes of 52 myopic patients (mean [+/- SD] age, 21 [+/- 2] yea...

Descripción completa

Detalles Bibliográficos
Autores: Pauné Fabré, Jaime|||0000-0002-2493-3791, Queiros, A, Lopes Ferreira, D, Faira Ribeiro, Miguel, Quevedo Junyent, Luisa Jesús|||0000-0002-0976-9372, Gonzalez Meijome, J.M.
Tipo de recurso: artículo
Fecha de publicación:2015
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/28200
Acceso en línea:https://hdl.handle.net/2117/28200
https://dx.doi.org/10.1097/OPX.0000000000000582
Access Level:acceso abierto
Palabra clave:Myopia
Contact lenses
Eye--Accommodation and refraction
myopia progression
gas permeable contact lens
peripheral refraction
SPECTACLE LENSES
RETINAL CONTOUR
REFRACTION
SOFT
ORTHOKERATOLOGY
PROGRESSION
CHILDREN
DESIGN
TRIAL
WEAR
Miopia
Lents de contacte
Ulls -- Acomodació i refracció
Àrees temàtiques de la UPC::Ciències de la visió::Contactologia
Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Oftalmologia
id ES_0a44567bed9c76fd5629eb7fadb52021
oai_identifier_str oai:upcommons.upc.edu:2117/28200
network_acronym_str ES
network_name_str España
repository_id_str
spelling Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic DefocusPauné Fabré, Jaime|||0000-0002-2493-3791Queiros, ALopes Ferreira, DFaira Ribeiro, MiguelQuevedo Junyent, Luisa Jesús|||0000-0002-0976-9372Gonzalez Meijome, J.M.MyopiaContact lensesEye--Accommodation and refractionmyopia progressiongas permeable contact lensperipheral refractionSPECTACLE LENSESRETINAL CONTOURREFRACTIONSOFTORTHOKERATOLOGYPROGRESSIONCHILDRENDESIGNTRIALWEARMiopiaLents de contacteUlls -- Acomodació i refraccióÀrees temàtiques de la UPC::Ciències de la visió::ContactologiaÀrees temàtiques de la UPC::Ciències de la salut::Medicina::OftalmologiaPurpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients.; Methods. Fifty-two right eyes of 52 myopic patients (mean [+/- SD] age, 21 [+/- 2] years) with spherical refractive errors ranging from -0.75 to -8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields.; Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p < 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding -1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error.; Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baseline spherical equivalent refractive error.20152015-05-0120152015-06-05journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/28200https://dx.doi.org/10.1097/OPX.0000000000000582reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivs 3.0 Spainhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/282002026-05-27T15:37:01Z
dc.title.none.fl_str_mv Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
title Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
spellingShingle Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
Pauné Fabré, Jaime|||0000-0002-2493-3791
Myopia
Contact lenses
Eye--Accommodation and refraction
myopia progression
gas permeable contact lens
peripheral refraction
SPECTACLE LENSES
RETINAL CONTOUR
REFRACTION
SOFT
ORTHOKERATOLOGY
PROGRESSION
CHILDREN
DESIGN
TRIAL
WEAR
Miopia
Lents de contacte
Ulls -- Acomodació i refracció
Àrees temàtiques de la UPC::Ciències de la visió::Contactologia
Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Oftalmologia
title_short Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
title_full Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
title_fullStr Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
title_full_unstemmed Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
title_sort Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus
dc.creator.none.fl_str_mv Pauné Fabré, Jaime|||0000-0002-2493-3791
Queiros, A
Lopes Ferreira, D
Faira Ribeiro, Miguel
Quevedo Junyent, Luisa Jesús|||0000-0002-0976-9372
Gonzalez Meijome, J.M.
author Pauné Fabré, Jaime|||0000-0002-2493-3791
author_facet Pauné Fabré, Jaime|||0000-0002-2493-3791
Queiros, A
Lopes Ferreira, D
Faira Ribeiro, Miguel
Quevedo Junyent, Luisa Jesús|||0000-0002-0976-9372
Gonzalez Meijome, J.M.
author_role author
author2 Queiros, A
Lopes Ferreira, D
Faira Ribeiro, Miguel
Quevedo Junyent, Luisa Jesús|||0000-0002-0976-9372
Gonzalez Meijome, J.M.
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv Myopia
Contact lenses
Eye--Accommodation and refraction
myopia progression
gas permeable contact lens
peripheral refraction
SPECTACLE LENSES
RETINAL CONTOUR
REFRACTION
SOFT
ORTHOKERATOLOGY
PROGRESSION
CHILDREN
DESIGN
TRIAL
WEAR
Miopia
Lents de contacte
Ulls -- Acomodació i refracció
Àrees temàtiques de la UPC::Ciències de la visió::Contactologia
Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Oftalmologia
topic Myopia
Contact lenses
Eye--Accommodation and refraction
myopia progression
gas permeable contact lens
peripheral refraction
SPECTACLE LENSES
RETINAL CONTOUR
REFRACTION
SOFT
ORTHOKERATOLOGY
PROGRESSION
CHILDREN
DESIGN
TRIAL
WEAR
Miopia
Lents de contacte
Ulls -- Acomodació i refracció
Àrees temàtiques de la UPC::Ciències de la visió::Contactologia
Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Oftalmologia
description Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients.; Methods. Fifty-two right eyes of 52 myopic patients (mean [+/- SD] age, 21 [+/- 2] years) with spherical refractive errors ranging from -0.75 to -8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields.; Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p < 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding -1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error.; Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baseline spherical equivalent refractive error.
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-05-01
2015
2015-06-05
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
AM
http://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/2117/28200
https://dx.doi.org/10.1097/OPX.0000000000000582
url https://hdl.handle.net/2117/28200
https://dx.doi.org/10.1097/OPX.0000000000000582
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:UPCommons. Portal del coneixement obert de la UPC
instname:Universitat Politècnica de Catalunya (UPC)
instname_str Universitat Politècnica de Catalunya (UPC)
reponame_str UPCommons. Portal del coneixement obert de la UPC
collection UPCommons. Portal del coneixement obert de la UPC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869403153989894144
score 15.300724