Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.

BACKGROUND: Fluorescence imaging (FI) is one of the methods to identify sentinel lymph nodes (SLNs). However, the procedure is technically complicated and requires procedural skills, as SLN biopsy must be conducted in dim light conditions. As an improved version of this method, we introduced a combi...

Descripción completa

Detalles Bibliográficos
Autores: Takemoto N, Koyanagi A, Yasuda M, Yamamoto H
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2018
País:España
Institución:Fundació Sant Joan de Déu
Repositorio:r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déu
OAI Identifier:oai:fsjd.fundanetsuite.com:p15038
Acceso en línea:https://fsjd.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=15038
Access Level:acceso abierto
Palabra clave:*Breast cancer
*Fluorescence
*Identification rate
*Indigo carmine
*Indocyanine green (ICG)
*Sentinel lymph node biopsy
id ES_09c3ce6730acd9fc5fc95a2425cfda91
oai_identifier_str oai:fsjd.fundanetsuite.com:p15038
network_acronym_str ES
network_name_str España
repository_id_str
spelling Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.Takemoto NKoyanagi AYasuda MYamamoto H*Breast cancer*Fluorescence*Identification rate*Indigo carmine*Indocyanine green (ICG)*Sentinel lymph node biopsyBACKGROUND: Fluorescence imaging (FI) is one of the methods to identify sentinel lymph nodes (SLNs). However, the procedure is technically complicated and requires procedural skills, as SLN biopsy must be conducted in dim light conditions. As an improved version of this method, we introduced a combined method (Combined mixed dye and fluorescence; CMF) consisting of indigo carmine blue dye and FI. The direct visualization of SLNs under shadowless surgical light conditions is facilitated by the addition of the blue dye. We compared the SLN detection rates of CMF with that of the indocyanine green (ICG) dye method (ICG-D). METHODS: A total of 202 patients with stage =IIA breast cancer who underwent breast conservative therapy with separate incision from January 2004 to February 2017 were reviewed. Details of the two methods are as follows: (1) ICG-D: 10 mg of ICG was used and the green-stained SLNs were resected via a 3-4 cm axillary incision; (2) CMF: A combination of 5 mg of ICG and 4-8 mg of indigo carmine was used. After a 1.5-2 cm incision was made near the point of disappearance of the fluorescence using Photodynamic Eye (PDE), the blue-stained SLNs were resected under shadowless surgical light conditions. RESULTS: There were 92 ICG-D and 110 CMF cases. CMF resulted in a significantly higher SLN detection rate than ICG-D (96.4% vs. 83.7%; p = 0.003). This difference was particularly notable in those aged =60 years (98.3% vs. 74.3%) and individuals with body mass index (BMI) =25 kg/m(2) (90.3% vs. 58.3%). CONCLUSION: CMF is an effective method to identify SLNs which is safe and efficient. CMF achieves a high SLN identification rate and most of this procedure is feasible under shadowless surgical light conditions. CMF can reliably perform SLN biopsy even in those aged =60 years and individuals with BMI = 25 kg/m(2).BMC2018info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://fsjd.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=15038BMC Womens HealthISSN: 14726874reponame:r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déuinstname:Fundació Sant Joan de DéuInglésinfo:eu-repo/semantics/openAccessoai:fsjd.fundanetsuite.com:p150382026-05-27T12:37:41Z
dc.title.none.fl_str_mv Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
title Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
spellingShingle Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
Takemoto N
*Breast cancer
*Fluorescence
*Identification rate
*Indigo carmine
*Indocyanine green (ICG)
*Sentinel lymph node biopsy
title_short Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
title_full Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
title_fullStr Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
title_full_unstemmed Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
title_sort Comparison of the indocyanine green dye method versus the combined method of indigo carmine blue dye with indocyanine green fluorescence imaging for sentinel lymph node biopsy in breast conservative therapy for stage =IIA breast cancer.
dc.creator.none.fl_str_mv Takemoto N
Koyanagi A
Yasuda M
Yamamoto H
author Takemoto N
author_facet Takemoto N
Koyanagi A
Yasuda M
Yamamoto H
author_role author
author2 Koyanagi A
Yasuda M
Yamamoto H
author2_role author
author
author
dc.subject.none.fl_str_mv *Breast cancer
*Fluorescence
*Identification rate
*Indigo carmine
*Indocyanine green (ICG)
*Sentinel lymph node biopsy
topic *Breast cancer
*Fluorescence
*Identification rate
*Indigo carmine
*Indocyanine green (ICG)
*Sentinel lymph node biopsy
description BACKGROUND: Fluorescence imaging (FI) is one of the methods to identify sentinel lymph nodes (SLNs). However, the procedure is technically complicated and requires procedural skills, as SLN biopsy must be conducted in dim light conditions. As an improved version of this method, we introduced a combined method (Combined mixed dye and fluorescence; CMF) consisting of indigo carmine blue dye and FI. The direct visualization of SLNs under shadowless surgical light conditions is facilitated by the addition of the blue dye. We compared the SLN detection rates of CMF with that of the indocyanine green (ICG) dye method (ICG-D). METHODS: A total of 202 patients with stage =IIA breast cancer who underwent breast conservative therapy with separate incision from January 2004 to February 2017 were reviewed. Details of the two methods are as follows: (1) ICG-D: 10 mg of ICG was used and the green-stained SLNs were resected via a 3-4 cm axillary incision; (2) CMF: A combination of 5 mg of ICG and 4-8 mg of indigo carmine was used. After a 1.5-2 cm incision was made near the point of disappearance of the fluorescence using Photodynamic Eye (PDE), the blue-stained SLNs were resected under shadowless surgical light conditions. RESULTS: There were 92 ICG-D and 110 CMF cases. CMF resulted in a significantly higher SLN detection rate than ICG-D (96.4% vs. 83.7%; p = 0.003). This difference was particularly notable in those aged =60 years (98.3% vs. 74.3%) and individuals with body mass index (BMI) =25 kg/m(2) (90.3% vs. 58.3%). CONCLUSION: CMF is an effective method to identify SLNs which is safe and efficient. CMF achieves a high SLN identification rate and most of this procedure is feasible under shadowless surgical light conditions. CMF can reliably perform SLN biopsy even in those aged =60 years and individuals with BMI = 25 kg/m(2).
publishDate 2018
dc.date.none.fl_str_mv 2018
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://fsjd.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=15038
url https://fsjd.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=15038
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv BMC
publisher.none.fl_str_mv BMC
dc.source.none.fl_str_mv BMC Womens Health
ISSN: 14726874
reponame:r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déu
instname:Fundació Sant Joan de Déu
instname_str Fundació Sant Joan de Déu
reponame_str r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déu
collection r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déu
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869403125017739264
score 15.81155