Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements
In this work, a full characterization of the new user-friendly version of the Atmospheric Radon MONitor (ARMON), used to measure very low activity concentrations of the radioactive radon gas in the outdoor atmosphere, is carried out. The ARMON is based on the electrostatic collection of 218Po+ parti...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/409178 |
| Acceso en línea: | https://hdl.handle.net/2117/409178 https://dx.doi.org/10.5194/amt-17-3047-2024 |
| Access Level: | acceso abierto |
| Palabra clave: | Radon Metrology Nuclear physics Radó Metrologia Física nuclear Àrees temàtiques de la UPC::Física |
| id |
ES_07a3e82ed2610fdf661345bc1aed4fc8 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/409178 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurementsCurcoll Masanes, Roger|||0000-0002-8025-673XGrossi, Claudia|||0000-0001-6678-4440Röttger, StefanVargas Drechsler, Arturo|||0000-0002-2576-9671RadonMetrologyNuclear physicsRadóMetrologiaFísica nuclearÀrees temàtiques de la UPC::FísicaIn this work, a full characterization of the new user-friendly version of the Atmospheric Radon MONitor (ARMON), used to measure very low activity concentrations of the radioactive radon gas in the outdoor atmosphere, is carried out. The ARMON is based on the electrostatic collection of 218Po+ particles on a semiconductor detector surface. A main advantage of this instrument is that it offers high-resolution alpha-energy spectra, which will allow us to separate radon progeny (210Po, 218Po, and 214Po). The monitor feature may also allow measurements of thoron (220Rn) by collection of 216Po+, although the instrument is not calibrated for this gas. In the paper, the physical principle; the hardware configuration; and the software development of the automatic and remotely controlled ARMON, conceived and constructed within the MAR2EA and the traceRadon projects, are described. The monitor efficiency and its linearity over a wide span of radon concentration activities have been evaluated and tested here using theoretical and experimental approaches. Finally, a complete budget analysis of the total uncertainty of the monitor was also achieved. Results from the application of a simplified theoretical approach show a detection efficiency for 218Po+ of about 0.0075¿(Bq¿m-3)-1¿s-1. The experimental approach, consisting of exposing the ARMON at controlled radon concentrations between a few hundreds to a few thousands of becquerels per cubic metre (Bq¿m-3), gives a detection efficiency for 218Po+ of 0.0057¿±¿0.0002¿(Bq¿m-3)¿s-1. This last value and its independence from the radon levels were also confirmed thanks to a new calibration method which allows us, using low-emanation sources, to obtain controlled radon levels of a few tens of becquerels per cubic metre (Bq¿m-3). The total uncertainty of the ARMON detection efficiency obtained for hourly radon concentrations above 5¿Bq¿m-3 was lower than 10¿% (k=¿1). The characteristic limits of the ARMON – being those dependent on the presence of thoron in the sampled air – were also calculated. A detection limit of 0.132¿Bq¿m-3 was estimated in the absence of thoron. At a typical thoron concentration at atmospheric sites of 0.017¿min-1, the detection limit was calculated to be 0.3¿Bq¿m-3, but this can be reduced if using a delay volume, obtaining a decision threshold of 0.0045¿Bq¿m-3. Current results may allow us to confirm that the ARMON is suitable to measure low-level radon activity concentrations (1–100¿Bq¿m-3) and to be used as a transfer standard to calibrate secondary atmospheric radon monitors.This research has been supported by the EU Horizon 2020 research and innovation programme (traceRadon project, grant no. 19ENV01) and the Agència de Gestió d'Ajuts Universitaris i de Recerca (MAR2EA; grant no. IU68-017047).European Geosciences Union (EGU)20242024-05-2120242024-06-04journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/409178https://dx.doi.org/10.5194/amt-17-3047-2024reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/4091782026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| title |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| spellingShingle |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements Curcoll Masanes, Roger|||0000-0002-8025-673X Radon Metrology Nuclear physics Radó Metrologia Física nuclear Àrees temàtiques de la UPC::Física |
| title_short |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| title_full |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| title_fullStr |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| title_full_unstemmed |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| title_sort |
Full characterization and calibration of a transfer standard monitor for atmospheric radon measurements |
| dc.creator.none.fl_str_mv |
Curcoll Masanes, Roger|||0000-0002-8025-673X Grossi, Claudia|||0000-0001-6678-4440 Röttger, Stefan Vargas Drechsler, Arturo|||0000-0002-2576-9671 |
| author |
Curcoll Masanes, Roger|||0000-0002-8025-673X |
| author_facet |
Curcoll Masanes, Roger|||0000-0002-8025-673X Grossi, Claudia|||0000-0001-6678-4440 Röttger, Stefan Vargas Drechsler, Arturo|||0000-0002-2576-9671 |
| author_role |
author |
| author2 |
Grossi, Claudia|||0000-0001-6678-4440 Röttger, Stefan Vargas Drechsler, Arturo|||0000-0002-2576-9671 |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Radon Metrology Nuclear physics Radó Metrologia Física nuclear Àrees temàtiques de la UPC::Física |
| topic |
Radon Metrology Nuclear physics Radó Metrologia Física nuclear Àrees temàtiques de la UPC::Física |
| description |
In this work, a full characterization of the new user-friendly version of the Atmospheric Radon MONitor (ARMON), used to measure very low activity concentrations of the radioactive radon gas in the outdoor atmosphere, is carried out. The ARMON is based on the electrostatic collection of 218Po+ particles on a semiconductor detector surface. A main advantage of this instrument is that it offers high-resolution alpha-energy spectra, which will allow us to separate radon progeny (210Po, 218Po, and 214Po). The monitor feature may also allow measurements of thoron (220Rn) by collection of 216Po+, although the instrument is not calibrated for this gas. In the paper, the physical principle; the hardware configuration; and the software development of the automatic and remotely controlled ARMON, conceived and constructed within the MAR2EA and the traceRadon projects, are described. The monitor efficiency and its linearity over a wide span of radon concentration activities have been evaluated and tested here using theoretical and experimental approaches. Finally, a complete budget analysis of the total uncertainty of the monitor was also achieved. Results from the application of a simplified theoretical approach show a detection efficiency for 218Po+ of about 0.0075¿(Bq¿m-3)-1¿s-1. The experimental approach, consisting of exposing the ARMON at controlled radon concentrations between a few hundreds to a few thousands of becquerels per cubic metre (Bq¿m-3), gives a detection efficiency for 218Po+ of 0.0057¿±¿0.0002¿(Bq¿m-3)¿s-1. This last value and its independence from the radon levels were also confirmed thanks to a new calibration method which allows us, using low-emanation sources, to obtain controlled radon levels of a few tens of becquerels per cubic metre (Bq¿m-3). The total uncertainty of the ARMON detection efficiency obtained for hourly radon concentrations above 5¿Bq¿m-3 was lower than 10¿% (k=¿1). The characteristic limits of the ARMON – being those dependent on the presence of thoron in the sampled air – were also calculated. A detection limit of 0.132¿Bq¿m-3 was estimated in the absence of thoron. At a typical thoron concentration at atmospheric sites of 0.017¿min-1, the detection limit was calculated to be 0.3¿Bq¿m-3, but this can be reduced if using a delay volume, obtaining a decision threshold of 0.0045¿Bq¿m-3. Current results may allow us to confirm that the ARMON is suitable to measure low-level radon activity concentrations (1–100¿Bq¿m-3) and to be used as a transfer standard to calibrate secondary atmospheric radon monitors. |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 2024-05-21 2024 2024-06-04 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AM http://purl.org/coar/version/c_ab4af688f83e57aa |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/409178 https://dx.doi.org/10.5194/amt-17-3047-2024 |
| url |
https://hdl.handle.net/2117/409178 https://dx.doi.org/10.5194/amt-17-3047-2024 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
European Geosciences Union (EGU) |
| publisher.none.fl_str_mv |
European Geosciences Union (EGU) |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869402994692325376 |
| score |
15,812429 |