Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block
Purpose: The objective of this study is to evaluate and compare the microtensile bond strength (μTBS) of four different self-adhesive resin cements to a resin-based ceramic CAD/CAM block, at the baseline, and after subjecting them to 5,000 thermo-cycles.Materials and Methods: Four self-adhesive dual...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | Costa Rica |
| Institución: | Universidad de Costa Rica |
| Repositorio: | Portal de Revistas UCR |
| Idioma: | inglés |
| OAI Identifier: | oai:portal.ucr.ac.cr:article/43670 |
| Acceso en línea: | https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670 |
| Access Level: | acceso abierto |
| Palabra clave: | CAD/CAM; Resin-ceramic; Microtensile; Adhesives; Resin cements; Dental bonding. CAD/CAM; Resina-cerámica; Microtensil; Fuerza de Tensión; Adhesivos; Cementos de resina; Adhesión dental. |
| id |
CR_bb22d0a448f256b8f90dfd92559984a9 |
|---|---|
| oai_identifier_str |
oai:portal.ucr.ac.cr:article/43670 |
| network_acronym_str |
CR |
| network_name_str |
Costa Rica |
| repository_id_str |
|
| dc.title.none.fl_str_mv |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block Resistencia adhesiva microtensil entre cementos de resina autoadhesivos y bloques de cerámica CAD/CAM a base de resina |
| title |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| spellingShingle |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block Berkman, Meriç CAD/CAM; Resin-ceramic; Microtensile; Adhesives; Resin cements; Dental bonding. CAD/CAM; Resina-cerámica; Microtensil; Fuerza de Tensión; Adhesivos; Cementos de resina; Adhesión dental. |
| title_short |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| title_full |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| title_fullStr |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| title_full_unstemmed |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| title_sort |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block |
| dc.creator.none.fl_str_mv |
Berkman, Meriç Tuncer, Safa Tekçe, Neslihan Karabay, Ferda Demirci, Mustafa |
| author |
Berkman, Meriç |
| author_facet |
Berkman, Meriç Tuncer, Safa Tekçe, Neslihan Karabay, Ferda Demirci, Mustafa |
| author_role |
author |
| author2 |
Tuncer, Safa Tekçe, Neslihan Karabay, Ferda Demirci, Mustafa |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
CAD/CAM; Resin-ceramic; Microtensile; Adhesives; Resin cements; Dental bonding. CAD/CAM; Resina-cerámica; Microtensil; Fuerza de Tensión; Adhesivos; Cementos de resina; Adhesión dental. |
| topic |
CAD/CAM; Resin-ceramic; Microtensile; Adhesives; Resin cements; Dental bonding. CAD/CAM; Resina-cerámica; Microtensil; Fuerza de Tensión; Adhesivos; Cementos de resina; Adhesión dental. |
| description |
Purpose: The objective of this study is to evaluate and compare the microtensile bond strength (μTBS) of four different self-adhesive resin cements to a resin-based ceramic CAD/CAM block, at the baseline, and after subjecting them to 5,000 thermo-cycles.Materials and Methods: Four self-adhesive dual-cured resin cements; G-CEM LinkAce (GC EUROPE, Leuven, Belgium), RelyX U200 (3M ESPE, Seefeld, Germany), Maxcem Elite (Kerr, CA, USA), TheraCem (Bisco, Schaumburg, USA) were applied to Cerasmart CAD/CAM blocks (GC EUROPE, Leuven, Belgium). CAD/CAM blocks were sectioned into sticks and subjected to µTBS tests at 24 hours, and the other half were subjected to tests after 5000 thermo-cycles. The data were tested by one-way variance analysis (p<0.05). Results: The highest bond strength values were observed in TheraCem, followed by G-CEM LinkAce and RelyX U200, respectively (p<0.05). At the baseline, G-CEM LinkAce, RelyX U200, and Maxcem Elite showed statistically similar results. After 5,000 thermal-cycles, a significant decrease was observed in the bond strength values of G-CEM LinkAce (p<0.05). Conclusion: Between the adhesive cements used in the study, TheraCem showed the highest micro-tensile bond strength values both in the baseline (24h) results, and after the 5,000 thermal-cycle aging procedures. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020-08-31 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/publishedVersion Article artículo original http://purl.org/coar/resource_type/c_2df8fbb1 info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670 10.15517/ijds.2021.43670 |
| url |
https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670 |
| identifier_str_mv |
10.15517/ijds.2021.43670 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43758 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43759 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43760 |
| dc.rights.none.fl_str_mv |
acceso abierto http://purl.org/coar/access_right/c_abf2 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
acceso abierto http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf text/html application/epub+zip |
| dc.publisher.none.fl_str_mv |
Universidad de Costa Rica |
| publisher.none.fl_str_mv |
Universidad de Costa Rica |
| dc.source.none.fl_str_mv |
Odovtos - International Journal of Dental Sciences; Vol. 23 No. 1 (2021): Odovtos-International Journal of Dental Sciences; 116-125 Odovtos International Journal of Dental Sciences; Vol. 23 Núm. 1 (2021): Odovtos-International Journal of Dental Sciences; 116-125 2215-3411 1659-1046 reponame:Portal de Revistas UCR instname:Universidad de Costa Rica instacron:UCR |
| instname_str |
Universidad de Costa Rica |
| instacron_str |
UCR |
| institution |
UCR |
| reponame_str |
Portal de Revistas UCR |
| collection |
Portal de Revistas UCR |
| repository.name.fl_str_mv |
Portal de Revistas UCR - Universidad de Costa Rica |
| repository.mail.fl_str_mv |
jorge.polanco@ucr.ac.cr |
| _version_ |
1849325444987355136 |
| spelling |
Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM BlockResistencia adhesiva microtensil entre cementos de resina autoadhesivos y bloques de cerámica CAD/CAM a base de resinaBerkman, MeriçTuncer, SafaTekçe, NeslihanKarabay, FerdaDemirci, MustafaCAD/CAM; Resin-ceramic; Microtensile; Adhesives; Resin cements; Dental bonding.CAD/CAM; Resina-cerámica; Microtensil; Fuerza de Tensión; Adhesivos; Cementos de resina; Adhesión dental.Purpose: The objective of this study is to evaluate and compare the microtensile bond strength (μTBS) of four different self-adhesive resin cements to a resin-based ceramic CAD/CAM block, at the baseline, and after subjecting them to 5,000 thermo-cycles.Materials and Methods: Four self-adhesive dual-cured resin cements; G-CEM LinkAce (GC EUROPE, Leuven, Belgium), RelyX U200 (3M ESPE, Seefeld, Germany), Maxcem Elite (Kerr, CA, USA), TheraCem (Bisco, Schaumburg, USA) were applied to Cerasmart CAD/CAM blocks (GC EUROPE, Leuven, Belgium). CAD/CAM blocks were sectioned into sticks and subjected to µTBS tests at 24 hours, and the other half were subjected to tests after 5000 thermo-cycles. The data were tested by one-way variance analysis (p<0.05). Results: The highest bond strength values were observed in TheraCem, followed by G-CEM LinkAce and RelyX U200, respectively (p<0.05). At the baseline, G-CEM LinkAce, RelyX U200, and Maxcem Elite showed statistically similar results. After 5,000 thermal-cycles, a significant decrease was observed in the bond strength values of G-CEM LinkAce (p<0.05). Conclusion: Between the adhesive cements used in the study, TheraCem showed the highest micro-tensile bond strength values both in the baseline (24h) results, and after the 5,000 thermal-cycle aging procedures. Propósito: Evaluar y comparar la resistencia adhesiva microtensil (μTBS) de cuatro cementos de resina autoadhesivos diferentes con un bloque CAD / CAM de cerámica a base de resina, antes y después de 5.000 ciclos de termociclado. Materiales y métodos: cuatro cementos de resina de doble curado autoadhesivos; G-CEM LinkAce (GC EUROPE, Lovaina, Bélgica), RelyX U200 (3M ESPE, Seefeld, Alemania), Maxcem Elite (Kerr, CA, EE. UU.), TheraCem (Bisco, Schaumburg, EE. UU.) fueron aplicados a bloques Cerasmart CAD/CAM (GC EUROPE, Lovaina, Bélgica). Los bloques CAD/CAM se seccionaron en barras y se sometieron a pruebas µTBS a las 24 horas, y la otra mitad se sometió a pruebas después de 5000 ciclos térmicos. Los datos fueron probados por análisis de varianza unidireccional (p<0.05). Resultados: Los valores más altos de fuerza de unión se observaron en TheraCem, seguido de G-CEM LinkAce y RelyX U200, respectivamente (p<0.05). En la línea de base, G-CEM LinkAce, RelyX U200, Maxcem Elite mostró resultados estadísticamente similares. Después de 5.000 procesos de ciclo térmico, se observó una disminución significativa en los valores de resistencia de la unión de G-CEM LinkAce (p<0.05). Conclusión: entre los cementos adhesivos utilizados en el estudio, TheraCem mostró los valores más altos de resistencia de la unión micro-extensible tanto en la línea de base (24 h) como después de 5,000 procedimientos de envejecimiento térmico.Universidad de Costa Rica2020-08-31info:eu-repo/semantics/publishedVersionArticleartículo originalhttp://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/articleapplication/pdftext/htmlapplication/epub+ziphttps://revistas.ucr.ac.cr/index.php/Odontos/article/view/4367010.15517/ijds.2021.43670Odovtos - International Journal of Dental Sciences; Vol. 23 No. 1 (2021): Odovtos-International Journal of Dental Sciences; 116-125Odovtos International Journal of Dental Sciences; Vol. 23 Núm. 1 (2021): Odovtos-International Journal of Dental Sciences; 116-1252215-34111659-1046reponame:Portal de Revistas UCRinstname:Universidad de Costa Ricainstacron:UCRenghttps://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43758https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43759https://revistas.ucr.ac.cr/index.php/Odontos/article/view/43670/43760acceso abiertohttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccess2021-06-09T21:50:14Zoai:portal.ucr.ac.cr:article/43670Portal de revistashttps://revistas.ucr.ac.cr/Universidadhttp://www.ucr.ac.crhttps://revistas.ucr.ac.cr/index.php/index/oaijorge.polanco@ucr.ac.crCosta RicaNo aplicaNo aplicaNo aplicaopendoar:2025-08-13T10:44:19.298Portal de Revistas UCR - Universidad de Costa Ricafalse |
| score |
15,198674 |