Internal structure of laboratory compacted warm mix asphalt
Warm mix asphalt (WMA) are asphalt mixtures fabricated at lower temperatures (i.e., 20 C to 50 C) than conventional hot mix asphalt (HMA). Therefore, as compared to HMA, WMA offer several engineering, economical, and environmental advantages. However, research is still required to identify the respo...
| Autores: | , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2012 |
| País: | Colombia |
| Institución: | Universidad Nacional de Colombia |
| Repositorio: | Repositorio UN |
| Idioma: | español |
| OAI Identifier: | oai:repositorio.unal.edu.co:unal/33408 |
| Acceso en línea: | https://repositorio.unal.edu.co/handle/unal/33408 http://bdigital.unal.edu.co/23488/ |
| Access Level: | acceso abierto |
| Palabra clave: | Warm mix asphalt hot mix asphalt mixture internal structure air voids X-ray Computed Tomography pavement structure |
| id |
CO_bb645abb5dd64efe9bb262de494335dc |
|---|---|
| oai_identifier_str |
oai:repositorio.unal.edu.co:unal/33408 |
| network_acronym_str |
CO |
| network_name_str |
Colombia |
| repository_id_str |
|
| spelling |
Internal structure of laboratory compacted warm mix asphaltAlvarez Lugo, Allex EduardoCarvajal Muñoz, Juan SebastianReyes Ortiz, Oscar JavierWarm mix asphalthot mix asphaltmixture internal structureair voidsX-ray Computed Tomographypavement structureWarm mix asphalt (WMA) are asphalt mixtures fabricated at lower temperatures (i.e., 20 C to 50 C) than conventional hot mix asphalt (HMA). Therefore, as compared to HMA, WMA offer several engineering, economical, and environmental advantages. However, research is still required to identify the response, properties, and performance of WMA, since they still constitute a relatively new technology. This paper focuses on the analysis of the internal structure of WMA specimens compacted using both the Superpave Gyratory Compactor (SGC) and the Texas Gyratory Compactor (TxGC). This analysis was conducted in terms of the air voids (AV) characteristics assessed by applying X-ray Computed Tomography and image analysis techniques. The results obtained suggest that the addition of WMA additives and corresponding reduction of the compaction temperature for SGC specimens did not lead to significant changes in the vertical distribution of total AV content as compared to that of the control-HMA. However, some differences were reported in terms of the AV size, which suggests the existence of discrepancies in the aggregate packing condition. Therefore, additional research is suggested to fully validate the equivalence of the internal structure of both WMA and HMA.Universidad Nacional de Colombia Sede Medellín2019-06-27T22:56:50Z2019-06-27T22:56:50Z2012Artículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTapplication/pdfapplication/pdftext/htmlhttps://repositorio.unal.edu.co/handle/unal/33408http://bdigital.unal.edu.co/23488/spahttp://revistas.unal.edu.co/index.php/dyna/article/view/20411Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDyna; Vol. 79, núm. 172 (2012); 38-45 DYNA; Vol. 79, núm. 172 (2012); 38-45 2346-2183 0012-7353Alvarez Lugo, Allex Eduardo and Carvajal Muñoz, Juan Sebastian and Reyes Ortiz, Oscar Javier (2012) Internal structure of laboratory compacted warm mix asphalt. Dyna; Vol. 79, núm. 172 (2012); 38-45 DYNA; Vol. 79, núm. 172 (2012); 38-45 2346-2183 0012-7353 .Derechos reservados - Universidad Nacional de ColombiaAtribución-NoComercial 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessreponame:Repositorio UNinstname:Universidad Nacional de Colombiainstacron:Universidad Nacional de Colombia2022-12-27T04:04:19Z |
| dc.title.none.fl_str_mv |
Internal structure of laboratory compacted warm mix asphalt |
| title |
Internal structure of laboratory compacted warm mix asphalt |
| spellingShingle |
Internal structure of laboratory compacted warm mix asphalt Alvarez Lugo, Allex Eduardo Warm mix asphalt hot mix asphalt mixture internal structure air voids X-ray Computed Tomography pavement structure |
| title_short |
Internal structure of laboratory compacted warm mix asphalt |
| title_full |
Internal structure of laboratory compacted warm mix asphalt |
| title_fullStr |
Internal structure of laboratory compacted warm mix asphalt |
| title_full_unstemmed |
Internal structure of laboratory compacted warm mix asphalt |
| title_sort |
Internal structure of laboratory compacted warm mix asphalt |
| dc.creator.none.fl_str_mv |
Alvarez Lugo, Allex Eduardo Carvajal Muñoz, Juan Sebastian Reyes Ortiz, Oscar Javier |
| author |
Alvarez Lugo, Allex Eduardo |
| author_facet |
Alvarez Lugo, Allex Eduardo Carvajal Muñoz, Juan Sebastian Reyes Ortiz, Oscar Javier |
| author_role |
author |
| author2 |
Carvajal Muñoz, Juan Sebastian Reyes Ortiz, Oscar Javier |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Warm mix asphalt hot mix asphalt mixture internal structure air voids X-ray Computed Tomography pavement structure |
| topic |
Warm mix asphalt hot mix asphalt mixture internal structure air voids X-ray Computed Tomography pavement structure |
| description |
Warm mix asphalt (WMA) are asphalt mixtures fabricated at lower temperatures (i.e., 20 C to 50 C) than conventional hot mix asphalt (HMA). Therefore, as compared to HMA, WMA offer several engineering, economical, and environmental advantages. However, research is still required to identify the response, properties, and performance of WMA, since they still constitute a relatively new technology. This paper focuses on the analysis of the internal structure of WMA specimens compacted using both the Superpave Gyratory Compactor (SGC) and the Texas Gyratory Compactor (TxGC). This analysis was conducted in terms of the air voids (AV) characteristics assessed by applying X-ray Computed Tomography and image analysis techniques. The results obtained suggest that the addition of WMA additives and corresponding reduction of the compaction temperature for SGC specimens did not lead to significant changes in the vertical distribution of total AV content as compared to that of the control-HMA. However, some differences were reported in terms of the AV size, which suggests the existence of discrepancies in the aggregate packing condition. Therefore, additional research is suggested to fully validate the equivalence of the internal structure of both WMA and HMA. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012 2019-06-27T22:56:50Z 2019-06-27T22:56:50Z |
| dc.type.none.fl_str_mv |
Artículo de revista info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 http://purl.org/coar/version/c_970fb48d4fbd8a85 Text http://purl.org/redcol/resource_type/ART |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/33408 http://bdigital.unal.edu.co/23488/ |
| url |
https://repositorio.unal.edu.co/handle/unal/33408 http://bdigital.unal.edu.co/23488/ |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://revistas.unal.edu.co/index.php/dyna/article/view/20411 Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna Dyna; Vol. 79, núm. 172 (2012); 38-45 DYNA; Vol. 79, núm. 172 (2012); 38-45 2346-2183 0012-7353 Alvarez Lugo, Allex Eduardo and Carvajal Muñoz, Juan Sebastian and Reyes Ortiz, Oscar Javier (2012) Internal structure of laboratory compacted warm mix asphalt. Dyna; Vol. 79, núm. 172 (2012); 38-45 DYNA; Vol. 79, núm. 172 (2012); 38-45 2346-2183 0012-7353 . |
| dc.rights.none.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia Atribución-NoComercial 4.0 Internacional http://creativecommons.org/licenses/by-nc/4.0/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos reservados - Universidad Nacional de Colombia Atribución-NoComercial 4.0 Internacional http://creativecommons.org/licenses/by-nc/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf text/html |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Colombia Sede Medellín |
| publisher.none.fl_str_mv |
Universidad Nacional de Colombia Sede Medellín |
| dc.source.none.fl_str_mv |
reponame:Repositorio UN instname:Universidad Nacional de Colombia instacron:Universidad Nacional de Colombia |
| instname_str |
Universidad Nacional de Colombia |
| instacron_str |
Universidad Nacional de Colombia |
| institution |
Universidad Nacional de Colombia |
| reponame_str |
Repositorio UN |
| collection |
Repositorio UN |
| _version_ |
1825052532071727104 |
| score |
15,808905 |