2050 LCOE (Levelized Cost of Energy) projection for a hybrid PV (photovoltaic)-CSP (concentrated solar power) plant in the Atacama Desert, Chile
This study calculates the LCOE (Levelized Cost of Energy) on the PSDA (Atacama Solar Platform) for a solar–solar energy mix with the objective of evaluate new options for continuous energy delivery. LCOE was calculated for three 50 MW (megawatt) power pla
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2016 |
| País: | Chile |
| Idioma: | inglés |
| OAI Identifier: | oai:repositorio.anid.cl:10533/239220 |
| Acceso en línea: | https://hdl.handle.net/10533/239220 |
| Access Level: | acceso abierto |
| Sumario: | This study calculates the LCOE (Levelized Cost of Energy) on the PSDA (Atacama Solar Platform) for a solar–solar energy mix with the objective of evaluate new options for continuous energy delivery. LCOE was calculated for three 50 MW (megawatt) power pla |
|---|