Effect of microwave disinfection on physical and mechanical properties of acrylic resins

This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A...

Descripción completa

Detalles Bibliográficos
Autores: Consani, Rafael Leonardo Xediek, Vieira, Erica Brenoe, Mesquita, Marcelo Ferraz, Mendes, Wilson Batista, Arioli-Filho, João Neudenir [UNESP]
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2008
País:Brasil
Institución:Universidade Estadual Paulista (UNESP)
Repositorio:Repositório Institucional da UNESP
Idioma:inglés
OAI Identifier:oai:repositorio.unesp.br:11449/70713
Acceso en línea:http://dx.doi.org/10.1590/S0103-64402008000400011
http://hdl.handle.net/11449/70713
Access Level:acceso abierto
Palabra clave:Acrylic resin
Flexural strength
Hardness
Impact
Microwave disinfection
acrylic acid resin
dental care
disinfection
equipment
hardness
materials testing
methodology
microwave radiation
pliability
radiation exposure
Acrylic Resins
Dental Stress Analysis
Disinfection
Equipment Contamination
Materials Testing
Microwaves
Pliability
Descripción
Sumario:This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.