Photoelastic and finite element stress analysis reliability for implant-supported system stress investigation
Aim: To compare the reliability between photoelastic and finite element (FE) analyses by evaluating the effect of different marginal misfit levels on the stresses generated on two different implant-supported systems using conventional and short implants. Methods: Two photoelastic models were obtaine...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2018 |
| País: | Brasil |
| Institución: | Universidade Federal de Minas Gerais (UFMG) |
| Repositorio: | Repositório Institucional da UFMG |
| Idioma: | inglés |
| OAI Identifier: | oai:repositorio.ufmg.br:1843/45447 |
| Acceso en línea: | https://doi.org/10.20396/bjos.v17i0.8652941 http://hdl.handle.net/1843/45447 |
| Access Level: | acceso abierto |
| Palabra clave: | Biomechanical phenomena Dental Implants Optical phenomena Finite element analysis |
| Sumario: | Aim: To compare the reliability between photoelastic and finite element (FE) analyses by evaluating the effect of different marginal misfit levels on the stresses generated on two different implant-supported systems using conventional and short implants. Methods: Two photoelastic models were obtained: model C with two conventional implants (4.1×11 mm); and model S with a conventional and a short implant (5×6 mm). Three-unit CoCr frameworks were fabricated simulating a superior first pre-molar (P) to first molar (M) fixed dental prosthesis. Different levels of misfit (μm) were selected based on the misfit average of 10 frameworks obtained by the single-screw test protocol: low (<20), medium (>20 and <40) and high (>40). Stress levels and distribution were measured by photoelastic analysis. A similar situation of the in vitro assay was designed and simulated by the in silico analysis. Maximum and minimum principal strain were recorded numerically and color-coded for the models. Von Mises Stress was obtained for the metallic components. Results:Photoelasticity and FE analyses showed similar tendency where the increase of misfit generates higher stress levels despite of the implant design. The short implant showed lower von Mises stress values; however, it presented stresses around its full length for the in vitro and in silico analysis. Also, model S showed higher μstrain values for all simulated misfit levels. The type of implant did not affect the stresses around pillar P. Conclusions:Photoelasticity and FEA are reliable methodologies presenting similarity for the investigation of the biomechanical behavior of implant-supported rehabilitations. |
|---|