Simulated cup/disc ratio: a tool for ophthalmologists

PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measur...

Descripción completa

Detalles Bibliográficos
Autores: Barbosa, Carolina Pelegrini [UNIFESP], Angelini, Pedro Felipe, Schor, Paulo [UNIFESP], Paranhos Junior, Augusto [UNIFESP]
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2010
País:Brasil
Institución:Universidade Federal de São Paulo (UNIFESP)
Repositorio:Repositório Institucional da UNIFESP
Idioma:inglés
OAI Identifier:oai:repositorio.unifesp.br:11600/5835
Acceso en línea:http://dx.doi.org/10.1590/S0004-27492010000400003
http://repositorio.unifesp.br/handle/11600/5835
Access Level:acceso abierto
Palabra clave:Optic disc
Glaucoma
Optic nerve diseases
Diagnostic techniques, ophthalmological
Internet
Measures
Disco óptico
Doenças do nervo óptico
Técnicas de diagnóstico oftalmológico
Medidas
Descripción
Sumario:PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.