Effects of curing protocol and storage time on the micro-hardness of resin cements used to lute fiber-reinforced resin posts

OBJECTIVES: To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100®, 3M-eSPe and Panavia F 2.0®, Kuraray) used for cementing fiberreinforced resin posts (Fibrekor® - Jeneric Pentron) under three different curing protocols and two water storage times. MATERIAL AND METHOD...

ver descrição completa

Detalhes bibliográficos
Autores: Ramos, Marcelo Barbosa, Pegoraro, Thiago Amadei, Pegoraro, Luiz Fernando, Carvalho, Ricardo Marins
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2012
País:Brasil
Recursos:Universidade de São Paulo (USP)
Repositorio:Journal of applied oral science (Online)
Idioma:inglés
OAI Identifier:oai:revistas.usp.br:article/47990
Acesso em linha:https://www.revistas.usp.br/jaos/article/view/47990
Access Level:acceso abierto
Palavra-chave:Resin cements
Adhesive cementation
Light curing
Dental adhesives
Descrição
Resumo:OBJECTIVES: To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100®, 3M-eSPe and Panavia F 2.0®, Kuraray) used for cementing fiberreinforced resin posts (Fibrekor® - Jeneric Pentron) under three different curing protocols and two water storage times. MATERIAL AND METHODS: Sixty 16mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: a) no light activation; b) light-activation immediately after seating the post, and; c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. RESULTS: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. CONCLUSIONS: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.