Photoelastic analysis to compare implant-retained and conventional obturator dentures

The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of...

Descripción completa

Detalles Bibliográficos
Autores: Goiato, Marcelo Coelho [UNESP], Ribeiro, Paula do Prado [UNESP], Pellizzer, Eduardo Piza [UNESP], Pesqueira, Aldieris Alves [UNESP], Haddad, Marcela Filie [UNESP], Santos, Daniela Micheline dos [UNESP], Moreno, Amalia [UNESP]
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2012
País:Brasil
Institución:Universidade Estadual Paulista (UNESP)
Repositorio:Repositório Institucional da UNESP
Idioma:inglés
OAI Identifier:oai:repositorio.unesp.br:11449/15361
Acceso en línea:http://dx.doi.org/10.1117/1.JBO.17.6.061203
http://hdl.handle.net/11449/15361
Access Level:acceso abierto
Palabra clave:dental implant
maxillectomy
photoelastic
denture liners
Descripción
Sumario:The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.6.061203]