Validação de método analítico por espectrofotometria UV para sistema emulsionado lipídico contendo benznidazol
A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2011 |
| País: | Brasil |
| Institución: | Universidade Estadual Paulista (UNESP) |
| Repositorio: | Repositório Institucional da UNESP |
| Idioma: | portugués |
| OAI Identifier: | oai:repositorio.unesp.br:11449/7957 |
| Acceso en línea: | http://dx.doi.org/10.1590/S0100-40422011000800028 http://hdl.handle.net/11449/7957 |
| Access Level: | acceso abierto |
| Palabra clave: | benznidazol lipid emulsions UV-Vis spectrophotometry |
| Sumario: | A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system. |
|---|