A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes

This work describes the investigation of a label-free immunosensor for the detection of aflatoxin B-1 (AFB(1)). CD-trodes (electrodes obtained from recordable compact disks) were used as low-cost and disposable transducers after modification with a self-assembled monolayer (SAM) of lipoic acid. The...

Descripción completa

Detalles Bibliográficos
Autores: Foguel, Marcos Vinicius [UNESP], Giordano, Gabriela Furlan [UNESP], Sylos, Celia Maria de [UNESP], Carlos, Iracilda Zeppone [UNESP], Pupim Ferreira, Antonio Aparecido [UNESP], Benedetti, Assis Vicente [UNESP], Yamanaka, Hideko [UNESP]
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2016
País:Brasil
Institución:Universidade Estadual Paulista (UNESP)
Repositorio:Repositório Institucional da UNESP
Idioma:inglés
OAI Identifier:oai:repositorio.unesp.br:11449/161873
Acceso en línea:http://dx.doi.org/10.3390/chemosensors4030017
http://hdl.handle.net/11449/161873
Access Level:acceso abierto
Palabra clave:aflatoxin B-1
immunosensor
electrochemical impedance spectroscopy
id BR_460c92104fbd074ece59f2306cf16307
oai_identifier_str oai:repositorio.unesp.br:11449/161873
network_acronym_str BR
network_name_str Brasil
repository_id_str
spelling A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodesaflatoxin B-1immunosensorelectrochemical impedance spectroscopyThis work describes the investigation of a label-free immunosensor for the detection of aflatoxin B-1 (AFB(1)). CD-trodes (electrodes obtained from recordable compact disks) were used as low-cost and disposable transducers after modification with a self-assembled monolayer (SAM) of lipoic acid. The anti-aflatoxin B1 antibody was immobilized via EDC/NHS activation, followed by blocking with bovine serum albumin and immunoassays with AFB(1). The optimization of analytical parameters and the detection were carried out using electrochemical impedance measurements. Using chemometric tools, the best conditions for the immunosensor development were defined as: anti-AFB(1) antibody at 1:2000 dilution and surface blocking with 0.5% bovine serum albumin, both incubated for 1 h, and antibody-antigen immunoreaction for 30 min. The impedimetric immunosensor showed a linear range from 5 x 10(-9) to 1 x 10(-7) mol . L-1 (1.56-31.2 ng . mL(-1)), limit of detection and limit of quantification, respectively, 3.6 x 10(-10) and 1.1 x 10(-9) mol . L-1 (0.11 and 0.34 ng.mL(-1)). The proposed immunosensor was applied to analyze peanut samples.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)FP7-PEOPLE-IRSESConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)UNESP Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, Rua Francisco Degni 55, BR-14800060 Araraquara, SP, BrazilUNESP Univ Estadual Paulista, Dept Food & Nutr, Sch Pharmaceut Sci, Rodovia Araraquara Jau,Km 01 S-N,Campos Ville, BR-14800903 Araraquara, SP, BrazilUNESP Univ Estadual Paulista, Dept Clin Anal, Sch Pharmaceut Sci, Rodovia Araraquara Jau,Km 01 S-N,Campos Ville, BR-14800903 Araraquara, SP, BrazilUNESP Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, Rua Francisco Degni 55, BR-14800060 Araraquara, SP, BrazilUNESP Univ Estadual Paulista, Dept Food & Nutr, Sch Pharmaceut Sci, Rodovia Araraquara Jau,Km 01 S-N,Campos Ville, BR-14800903 Araraquara, SP, BrazilUNESP Univ Estadual Paulista, Dept Clin Anal, Sch Pharmaceut Sci, Rodovia Araraquara Jau,Km 01 S-N,Campos Ville, BR-14800903 Araraquara, SP, BrazilFAPESP: 2008/07729-8FP7-PEOPLE-IRSES: 2008-230849CNPq: 309275/2012-1Mdpi AgUniversidade Estadual Paulista (Unesp)2018-11-26T17:04:29Z2018-11-26T17:04:29Z2016-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article10application/pdfhttp://dx.doi.org/10.3390/chemosensors4030017Chemosensors. Basel: Mdpi Ag, v. 4, n. 3, 10 p., 2016.2227-9040http://hdl.handle.net/11449/16187310.3390/chemosensors4030017WOS:000382480000007WOS000382480000007.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengChemosensorsinfo:eu-repo/semantics/openAccessFoguel, Marcos Vinicius [UNESP]Giordano, Gabriela Furlan [UNESP]Sylos, Celia Maria de [UNESP]Carlos, Iracilda Zeppone [UNESP]Pupim Ferreira, Antonio Aparecido [UNESP]Benedetti, Assis Vicente [UNESP]Yamanaka, Hideko [UNESP]2025-05-28T07:53:08Zoai:repositorio.unesp.br:11449/161873Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-05-28T07:53:08Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
title A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
spellingShingle A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
Foguel, Marcos Vinicius [UNESP]
aflatoxin B-1
immunosensor
electrochemical impedance spectroscopy
title_short A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
title_full A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
title_fullStr A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
title_full_unstemmed A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
title_sort A Low-Cost Label-Free AFB(1) Impedimetric Immunosensor Based on Functionalized CD-Trodes
dc.creator.none.fl_str_mv Foguel, Marcos Vinicius [UNESP]
Giordano, Gabriela Furlan [UNESP]
Sylos, Celia Maria de [UNESP]
Carlos, Iracilda Zeppone [UNESP]
Pupim Ferreira, Antonio Aparecido [UNESP]
Benedetti, Assis Vicente [UNESP]
Yamanaka, Hideko [UNESP]
author Foguel, Marcos Vinicius [UNESP]
author_facet Foguel, Marcos Vinicius [UNESP]
Giordano, Gabriela Furlan [UNESP]
Sylos, Celia Maria de [UNESP]
Carlos, Iracilda Zeppone [UNESP]
Pupim Ferreira, Antonio Aparecido [UNESP]
Benedetti, Assis Vicente [UNESP]
Yamanaka, Hideko [UNESP]
author_role author
author2 Giordano, Gabriela Furlan [UNESP]
Sylos, Celia Maria de [UNESP]
Carlos, Iracilda Zeppone [UNESP]
Pupim Ferreira, Antonio Aparecido [UNESP]
Benedetti, Assis Vicente [UNESP]
Yamanaka, Hideko [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.subject.por.fl_str_mv aflatoxin B-1
immunosensor
electrochemical impedance spectroscopy
topic aflatoxin B-1
immunosensor
electrochemical impedance spectroscopy
description This work describes the investigation of a label-free immunosensor for the detection of aflatoxin B-1 (AFB(1)). CD-trodes (electrodes obtained from recordable compact disks) were used as low-cost and disposable transducers after modification with a self-assembled monolayer (SAM) of lipoic acid. The anti-aflatoxin B1 antibody was immobilized via EDC/NHS activation, followed by blocking with bovine serum albumin and immunoassays with AFB(1). The optimization of analytical parameters and the detection were carried out using electrochemical impedance measurements. Using chemometric tools, the best conditions for the immunosensor development were defined as: anti-AFB(1) antibody at 1:2000 dilution and surface blocking with 0.5% bovine serum albumin, both incubated for 1 h, and antibody-antigen immunoreaction for 30 min. The impedimetric immunosensor showed a linear range from 5 x 10(-9) to 1 x 10(-7) mol . L-1 (1.56-31.2 ng . mL(-1)), limit of detection and limit of quantification, respectively, 3.6 x 10(-10) and 1.1 x 10(-9) mol . L-1 (0.11 and 0.34 ng.mL(-1)). The proposed immunosensor was applied to analyze peanut samples.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-01
2018-11-26T17:04:29Z
2018-11-26T17:04:29Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.3390/chemosensors4030017
Chemosensors. Basel: Mdpi Ag, v. 4, n. 3, 10 p., 2016.
2227-9040
http://hdl.handle.net/11449/161873
10.3390/chemosensors4030017
WOS:000382480000007
WOS000382480000007.pdf
url http://dx.doi.org/10.3390/chemosensors4030017
http://hdl.handle.net/11449/161873
identifier_str_mv Chemosensors. Basel: Mdpi Ag, v. 4, n. 3, 10 p., 2016.
2227-9040
10.3390/chemosensors4030017
WOS:000382480000007
WOS000382480000007.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Chemosensors
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 10
application/pdf
dc.publisher.none.fl_str_mv Mdpi Ag
publisher.none.fl_str_mv Mdpi Ag
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1853672358241370112
score 15.301603