Effects of soil-structure interaction in seismic analysis of buildings with multiple pressurized tuned liquid column dampers

In this paper soil-structure interaction (SSI) effects are investigated while an array of Pressurized Tuned Liquid Column Dampers (PTLCD) is employed for seismic vibration control of buildings. This device represents the most general case of a passive damper, with different reduction options to othe...

Descripción completa

Detalles Bibliográficos
Autores: Mendes, Maurício Vitali, Ribeiro, Paulo Marcelo Vieira, Pedroso, Lineu José
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2019
País:Brasil
Institución:Universidade de Brasília (UnB)
Repositorio:Repositório Institucional da UnB
Idioma:inglés
OAI Identifier:oai:repositorio.unb.br:10482/36546
Acceso en línea:https://repositorio.unb.br/handle/10482/36546
https://doi.org/10.1590/1679-78255707
http://orcid.org/0000-0001-8779-4373
http://orcid.org/0000-0002-9261-8953
http://orcid.org/0000-0002-2734-3260
Access Level:acceso abierto
Palabra clave:Amortecedores
Análise sísmica
Vibração - controle
Edifícios
Descripción
Sumario:In this paper soil-structure interaction (SSI) effects are investigated while an array of Pressurized Tuned Liquid Column Dampers (PTLCD) is employed for seismic vibration control of buildings. This device represents the most general case of a passive damper, with different reduction options to other control devices obtained by simplifying the involved parameters. Soil conditions considerably affect the control device functioning, because dynamic parameters such as natural frequency, damping factor, and natural modes depend on the soil properties. A simplified mathematical model is developed for the building with multiple degrees of freedom connected to a flexible base. For the time-domain analysis, a computational routine is developed for the linearization of the equilibrium equations of the PTLCD, as well as details for the reduction to the other types of passive dampers. Several numerical examples are selected for the analysis of the damper efficiency in reducing seismic vibration considering SSI. These simulations include Kobe earthquake data, which is applied to the model to evaluate the device performance under different scenarios. It is verified the influence of SSI in the natural frequency and structural response, which is related to the earthquake frequency components. Results confirm that the array of PTLCD’s can reduce the vibration amplitudes, being more effective for soils with higher stiffness values.