Desenvolvimento de eletrodo de filme de bismuto depositado sobre cobre para aplicações eletroanalíticas

On this work is described the development of bismuth film electrode deposited over copper substrate for electroanalytical applications. The bismuth film electrode was deposited ex situ over a copper substrate. The electrodeposition of Bi was carried out applying a constant potential of -150 mV durin...

ver descrição completa

Detalhes bibliográficos
Autor: Nunes, Luiza Maria da Silva
Formato: tesis de maestría
Estado:Versión publicada
Fecha de publicación:2007
País:Brasil
Recursos:Universidade Federal de São Carlos (UFSCAR)
Repositorio:Repositório Institucional da UFSCAR
Idioma:portugués
OAI Identifier:oai:repositorio.ufscar.br:20.500.14289/6412
Acesso em linha:https://repositorio.ufscar.br/handle/20.500.14289/6412
Access Level:acceso abierto
Palavra-chave:Química analitica
Eletrodeposição
Metais pesados
Eletrodo de bismuto
CIENCIAS EXATAS E DA TERRA::QUIMICA
Descrição
Resumo:On this work is described the development of bismuth film electrode deposited over copper substrate for electroanalytical applications. The bismuth film electrode was deposited ex situ over a copper substrate. The electrodeposition of Bi was carried out applying a constant potential of -150 mV during 300 s. The plating solution was composed by 0.02 mol L-1 Bi(NO)3 in 1.0 mol L-1 hydrochloride acid with or not 0.08 mol L-1 sodium citrate, the electrodes obtained from these solutions were nominated Bi-Cit008 and Bi-HCl, respectively. The bismuth film characterization was carried out by Field Emission Gun Scanning Electron Microscopy (FEG-SEM), Scanning Electron Microscopy with Energy Dispersive X-ray analysis (MEV-EDX) and X-Ray Diffraction analysis. The FEG-SEM and MEV-EDX analysis of bismuth film showed that the morphology of the deposits were strongly dependent of the plating solution composition. X-Ray diffraction analysis showed a single rhombohedral and cubic phase for the two bismuth film electrodes analyzed. The Bi-HCl and Bi-Cit008 electrodes showed a good cathodic potential window from -300 mV to -1200 mV. Both electrodes, exhibited a good analytical response for cadmium and lead by means of square wave anodic stripping voltammetry technique. For the lead determination, Bi-HCl and Bi-Cit008 electrodes showed a detection limit of 2.8 x 10-8 mol L-1 and 2.5 x 10-8 mol L-1, respectively in a concentration range from 9.6 x 10-6 to 5.7 x 10-5 mol L-1. For the cadmium determination, Bi-HCl and Bi-Cit008 electrodes presented a detection limit of 1.1 x 10-6 mol L-1 and 6.3 x 10-8 mol L-1, respectively in the concentration range from 1.7 x 10-5 to 12.3 x 10-5 mol L-1. Both electrodes, presented analytical response with good resolution without baseline dislocation, therefore, Bi-Cit008 had best analytical performance.