Tribocorrosion behaviour of bio-functionalized porous Ti surfaces obtained by two-step anodic treatment
A bio-functionalized porous surface was obtained on Ti by a two-step anodic treatment and its corrosion and tribocorrosion behaviour were evaluated. The first-step provided macro-porosity while the second-step, a bio-functionalization process by micro-arc oxidation (MAO), provided an oxide layer (an...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | Brasil |
| Institución: | Universidade Estadual Paulista (UNESP) |
| Repositorio: | Repositório Institucional da UNESP |
| Idioma: | inglés |
| OAI Identifier: | oai:repositorio.unesp.br:11449/198558 |
| Acceso en línea: | http://dx.doi.org/10.1016/j.corsci.2020.108467 http://hdl.handle.net/11449/198558 |
| Access Level: | acceso abierto |
| Palabra clave: | Anodic treatment Corrosion Micro-arc oxidation (MAO) Titanium Tribocorrosion |
| Sumario: | A bio-functionalized porous surface was obtained on Ti by a two-step anodic treatment and its corrosion and tribocorrosion behaviour were evaluated. The first-step provided macro-porosity while the second-step, a bio-functionalization process by micro-arc oxidation (MAO), provided an oxide layer (anatase + rutile) with micro-pores and bio-active elements (Ca + P). Corrosion and tribocorrosion behaviour were improved due to the protective role given by the oxide layer formed on the second-step. Tribocorrosion mechanisms for the bio-functionalized porous structures are presented. |
|---|