Estudo metrológico volumétrico de bombas de infusão peristálticas lineares

This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pu...

Descripción completa

Detalles Bibliográficos
Autor: Dumas Junior, Adair
Tipo de recurso: tesis de maestría
Estado:Versión publicada
Fecha de publicación:2016
País:Brasil
Institución:Universidade Tecnológica Federal do Paraná (UTFPR)
Repositorio:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
Idioma:portugués
OAI Identifier:oai:repositorio.utfpr.edu.br:1/2039
Acceso en línea:http://repositorio.utfpr.edu.br/jspui/handle/1/2039
Access Level:acceso abierto
Palabra clave:Bombas de infusão de drogas - Calibração
Medição
Teoria dos erros
Instrumentos e aparelhos médicos - Testes
Engenharia biomédica
Drug infusion pumps - Calibration
Mensuration
Error analysis (Mathematics)
Medical instruments and apparatus - Testing
Biomedical engineering
CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA::ENGENHARIA MEDICA::INSTRUMENTACAO ODONTOLOGICA E MEDICO-HOSPITALAR
Descripción
Sumario:This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.