Methotrexate locally released from poly (caprolactone) implants : inhibition of the inflammatory angiogenesis response in a murine sponge model and the absence of systemic toxicity.

In this study, the methotrexate (MTX) was incorporated into the poly(-caprolactone) (PCL) to design implants (MTX PCL implants) aiming the local treatment of inflammatory angiogenesis diseases without causing systemic side effects. Sponges were inserted into the subcutaneous tissue of mice as a fra...

Descripción completa

Detalles Bibliográficos
Autores: Oliveira, Leandro Gonzaga de, Figueiredo, Letícia Aparecida, Cunha, Gabriella Maria Fernandes, Oliveira, Laser Antônio Machado de, Miranda, Marina Barcelos de, Silva, Gisele Rodrigues da, Moura, Sandra Aparecida Lima de
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2015
País:Brasil
Institución:Universidade Federal de Ouro Preto (UFOP)
Repositorio:Repositório Institucional da UFOP
Idioma:inglés
OAI Identifier:oai:repositorio.ufop.br:123456789/6627
Acceso en línea:http://www.repositorio.ufop.br/handle/123456789/6627
https://doi.org/10.1002/jps.24569
Access Level:acceso abierto
Palabra clave:Biodegradable polymers
Biomaterials
Controlled release/delivery
Targeted drug delivery
Polymeric drug delivery systems
Descripción
Sumario:In this study, the methotrexate (MTX) was incorporated into the poly(-caprolactone) (PCL) to design implants (MTX PCL implants) aiming the local treatment of inflammatory angiogenesis diseases without causing systemic side effects. Sponges were inserted into the subcutaneous tissue of mice as a framework for fibrovascular tissue growth. After 4 days, MTX PCL implants were also introduced, and anti-inflammatory, antiangiogenic, and antifibrogenic activities of the MTX were determined. MTX reduced the vascularization (hemoglobin content), the neutrophil, and monocyte/macrophage infiltration (MPO and NAG activities, respectively), and the collagen deposition in sponges. MTX reduced tumor necrosis factor-_ and IL-6 levels, demonstrating its local antiangiogenic and anti-inflammatory effects. Furthermore, hepatotoxicity, nephrotoxicity, and myelotoxicity, which could be induced by the drug, were evaluated. However, MTX did not promote toxicity to these organs, as the levels of AST and ALT (hepatic markers) and creatinine and urea (renal markers) were not increased, and the complete blood count was not decreased. In conclusion, MTX PCL implants demonstrated to be effective in regulating the components of the inflammatory angiogenesis locally established, and presented an acceptable safety profile. C _ 2015Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci.