Exploring digital filters for internal root resorption : how can we improve the diagnosis of small lesions?
Objectives: This study aimed to evaluate the impact of enhancement filters in detecting small simulated internal root resorptions (IRR). Methods: Forty-two extracted human teeth were sectioned, connected, and stored in a dry human jaw and X-rayed with photostimulable phosphor plates (PSPs), composin...
| Autores: | , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2022 |
| País: | Brasil |
| Institución: | Universidade Federal do Rio Grande do Sul (UFRGS) |
| Repositorio: | Repositório Institucional da UFRGS |
| Idioma: | inglés |
| OAI Identifier: | oai:www.lume.ufrgs.br:10183/264274 |
| Acceso en línea: | http://hdl.handle.net/10183/264274 |
| Access Level: | acceso abierto |
| Palabra clave: | Reabsorção da raiz Radiografia dentária Intensificação de imagem radiográfica Root resorption Dental digital radiography Radiographic image enhancement |
| Sumario: | Objectives: This study aimed to evaluate the impact of enhancement filters in detecting small simulated internal root resorptions (IRR). Methods: Forty-two extracted human teeth were sectioned, connected, and stored in a dry human jaw and X-rayed with photostimulable phosphor plates (PSPs), composing the control group (CG). In the middle-third of the root canals, IRR lesions were simulated using Da Silveira protocol. Later, the specimens were X-rayed to create the test group (TG). All images acquired were exported with seven enhancement filters plus the original image. Three examiners used a five-point Likert scale to evaluate the images regarding the presence/absence of IRR. Diagnostic efficacy was assessed from sensitivity and specificity results. Comparison among filters was performed by using receiver operating characteristic (ROC) curve analysis. Results: Moderate values of Kappa interexaminer (0.403–0.620) and high values of Kappa intraexaminer (0.757–0.915) were observed. The best performance occurred in the CG (p < 0.05). Original images presented the greatest sensitivity and area under the ROC curve (0.595–0.750), while the Endo filter presented the greatest specificity (0.952). Inversion and Pseudo-3D images produced the greatest doubt in the diagnosis, significant for CG with the Pseudo-3D filter (p < 0.05). Conclusions: The Original and ‘Endo’ filters should be chosen as it offers greater diagnostic ability and allows more confidence during the evaluation. |
|---|