Latin American dose survey results in mammography studies under IAEA Programme: Radiological Protection of Patients in Medical Exposures (TSA3)

Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Expo...

Descripción completa

Detalles Bibliográficos
Autores: Mora, Patricia, Blanco, Susana Alicia Ana, Khoury, Helen, Leyton, Fernando, Cárdenas, Juan, Defaz, María Yolanda, Escobar, Carolina, Flaviano Telón, García Aguilar, Juán, Roas, Norma, Gamarra, Mirta, Blanco, Daniel, Quintero, Ana Rosa, Nader, Alejandro
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2014
País:Argentina
Institución:Consejo Nacional de Investigaciones Científicas y Técnicas
Repositorio:CONICET Digital (CONICET)
Idioma:inglés
OAI Identifier:oai:ri.conicet.gov.ar:11336/103885
Acceso en línea:http://hdl.handle.net/11336/103885
Access Level:acceso abierto
Palabra clave:MAMMOGRAPHY
QUALITY CONTROL
MEAN GLANDULAR DOSE
LATIN AMERICAN
IAEA
https://purl.org/becyt/ford/3.3
https://purl.org/becyt/ford/3
Descripción
Sumario:Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimization of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analog and digital equipment that will direct future optimization activities, towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-2009) 24 institutions participated with analog equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. Mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For phase two, RLA9/067 (2010-2011), it was decided to include also digital systems in order to see their impact in future dose optimization activities. Any new country that joined the project received training in the activities through IAEA expert missions. 29 new institutions participated (9 analog and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them DG (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO respectively: RLA9/057 (analog) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analog) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO respectively, computed radiography (CR) systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3mGy), it can be observed that there is enough room to start optimization processes in Latin America (LA); several countries or even particular institutions have values much higher than the 3mGy. Main issues to address are: lack of well established Quality Assurance (QA) programs for mammography, not enough medical physicists with training in mammography, an increase in patient doses with the introduction of digital equipment and to create awareness on radiation risk and optimization strategies,