Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI
Despite a large amount of publications on Fuzzy Mathematical Morphology, little effort was done on systematic evaluation of the performance of this technique. The goal of this work is to compare the robustness against noise of Fuzzy and non Fuzzy Morphological operators when applied to noisy images....
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2014 |
| País: | Argentina |
| Institución: | Consejo Nacional de Investigaciones Científicas y Técnicas |
| Repositorio: | CONICET Digital (CONICET) |
| Idioma: | inglés |
| OAI Identifier: | oai:ri.conicet.gov.ar:11336/25766 |
| Acceso en línea: | http://hdl.handle.net/11336/25766 |
| Access Level: | acceso abierto |
| Palabra clave: | Biomedical Images Digital Image Processing Mathematical Morphology Fuzzy Mathematical Morphology https://purl.org/becyt/ford/2.2 https://purl.org/becyt/ford/2 |
| id |
AR_7a2ea2d3114ffdcc80959e10caf19737 |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/25766 |
| network_acronym_str |
AR |
| network_name_str |
Argentina |
| repository_id_str |
|
| spelling |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRIBouchet, AgustinaBenalcazar Palacios, FreddyBrun, MarcelBallarin, Virginia LauraBiomedical ImagesDigital Image ProcessingMathematical MorphologyFuzzy Mathematical Morphologyhttps://purl.org/becyt/ford/2.2https://purl.org/becyt/ford/2Despite a large amount of publications on Fuzzy Mathematical Morphology, little effort was done on systematic evaluation of the performance of this technique. The goal of this work is to compare the robustness against noise of Fuzzy and non Fuzzy Morphological operators when applied to noisy images. Magnetic Resonance Images (MRI) of the brain are a kind of images containing some characteristics that make fuzzy operators an interesting choice, because of their intrinsic noise and imprecision. The robustness was evaluated as the degree in which the results of the operators are not affected by artificial noise in the images. In the analysis we compared different implementation of Fuzzy Mathematical Morphology, and observed that in most of the cases they show higher robustness against noise than the classical morphological operatorsFil: Bouchet, Agustina. Universidad Nacional de Mar del Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Benalcazar Palacios, Freddy. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro; Argentina. Escuela Superior Politécnica de Chimborazo; EcuadorFil: Brun, Marcel. Universidad Nacional de Mar del Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Ballarin, Virginia Laura. Universidad Nacional de Mar del Plata. Facultad de Ingeniería; ArgentinaPlanta Piloto de Ingeniería Química2014-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/25766Bouchet, Agustina; Benalcazar Palacios, Freddy; Brun, Marcel; Ballarin, Virginia Laura; Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI; Planta Piloto de Ingeniería Química; Latin American Applied Research; 44; 3; 2-2014; 231-2360327-07931851-8796CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.laar.uns.edu.ar/indexes/i44_03.htminfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2024-05-08T14:26:11Zoai:ri.conicet.gov.ar:11336/25766instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982024-05-08 14:26:12.177CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| title |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| spellingShingle |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI Bouchet, Agustina Biomedical Images Digital Image Processing Mathematical Morphology Fuzzy Mathematical Morphology https://purl.org/becyt/ford/2.2 https://purl.org/becyt/ford/2 |
| title_short |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| title_full |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| title_fullStr |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| title_full_unstemmed |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| title_sort |
Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI |
| dc.creator.none.fl_str_mv |
Bouchet, Agustina Benalcazar Palacios, Freddy Brun, Marcel Ballarin, Virginia Laura |
| author |
Bouchet, Agustina |
| author_facet |
Bouchet, Agustina Benalcazar Palacios, Freddy Brun, Marcel Ballarin, Virginia Laura |
| author_role |
author |
| author2 |
Benalcazar Palacios, Freddy Brun, Marcel Ballarin, Virginia Laura |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Biomedical Images Digital Image Processing Mathematical Morphology Fuzzy Mathematical Morphology https://purl.org/becyt/ford/2.2 https://purl.org/becyt/ford/2 |
| topic |
Biomedical Images Digital Image Processing Mathematical Morphology Fuzzy Mathematical Morphology https://purl.org/becyt/ford/2.2 https://purl.org/becyt/ford/2 |
| description |
Despite a large amount of publications on Fuzzy Mathematical Morphology, little effort was done on systematic evaluation of the performance of this technique. The goal of this work is to compare the robustness against noise of Fuzzy and non Fuzzy Morphological operators when applied to noisy images. Magnetic Resonance Images (MRI) of the brain are a kind of images containing some characteristics that make fuzzy operators an interesting choice, because of their intrinsic noise and imprecision. The robustness was evaluated as the degree in which the results of the operators are not affected by artificial noise in the images. In the analysis we compared different implementation of Fuzzy Mathematical Morphology, and observed that in most of the cases they show higher robustness against noise than the classical morphological operators |
| publishDate |
2014 |
| dc.date.none.fl_str_mv |
2014-02 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/25766 Bouchet, Agustina; Benalcazar Palacios, Freddy; Brun, Marcel; Ballarin, Virginia Laura; Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI; Planta Piloto de Ingeniería Química; Latin American Applied Research; 44; 3; 2-2014; 231-236 0327-0793 1851-8796 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/25766 |
| identifier_str_mv |
Bouchet, Agustina; Benalcazar Palacios, Freddy; Brun, Marcel; Ballarin, Virginia Laura; Performance Analysis of Fuzzy Mathematical Morphology Operators on noisy MRI; Planta Piloto de Ingeniería Química; Latin American Applied Research; 44; 3; 2-2014; 231-236 0327-0793 1851-8796 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.laar.uns.edu.ar/indexes/i44_03.htm |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Planta Piloto de Ingeniería Química |
| publisher.none.fl_str_mv |
Planta Piloto de Ingeniería Química |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1799196398903623680 |
| score |
15.811543 |