This research aims to design a sensor-based hand-eye coordination measuring tool and test its validity and reliability. A total of 9 experts were involved in assessing its feasibility, each of them 3 sports measurement experts, 3 motor experts, and 3 technology experts. Meanwhile, 50 students at one...

Descripción completa

Detalles Bibliográficos
Autores: Irawan, Roma, Yenes, Ronni, Mario, Deby Tri, Komaini, Anton, García Fernández, Jerónimo, Orhan, Bekir Erhan, Ayubi, Novadri
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Universidad de Sevilla (US)
Repositorio:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:idus.us.es:11441/169719
Acceso en línea:https://hdl.handle.net/11441/169719
https://doi.org/10.47197/retos.v56.103610
Access Level:acceso abierto
Palabra clave:Validity
Reliability
Coordination
Sensors
Validez
Confiabilidad
Coordinación
Descripción
Sumario:This research aims to design a sensor-based hand-eye coordination measuring tool and test its validity and reliability. A total of 9 experts were involved in assessing its feasibility, each of them 3 sports measurement experts, 3 motor experts, and 3 technology experts. Meanwhile, 50 students at one of the Faculty of Sports Sciences, Indonesia participated in field trials. Participants were stu- dents taking physical condition courses (aged 18-20 years), consisting of male (n1=30) and female (n2=20). A validation questionnaire was prepared and discussed with experts as a guide in providing an assessment of the relevance of the instrument (suitability, accuracy, ease, and practicality of the tool), and test-retest reliability for field trials carried out twice with the difference between the first and second tests being one week. Data were analyzed using Aiken's V Index, Intraclass Correlation Coefficient (ICC), and Pearson correla- tion. The research results showed that the assessment of all aspects of the measuring instrument was in the high category, and the ICC value also showed no differences between assessments (P>0.05). Then, the test-retest reliability testing results obtained a significant regression analysis with a high correlation coefficient (r=0.801; P<0.05). In conclusion, this measuring tool can collect data to improve performance in sports involving hand-eye coordination (such as volleyball, badminton, tennis, basketball, hockey, martial arts and other sports that predominantly use the hands), both for coaches, athletes and sports practitioners.